2
Introduction
Model C723
131028
Safety
We, at Taylor Company, are committed to
manufacturing safe operating and serviceable
equipment. The many built-in safety features that
are part of all Taylor equipment are aimed at
protecting operators and trained service technicians
alike.
This manual is intended exclusively for
Taylor authorized service personnel.
DO NOT
attempt to run the equipment
unless you have been properly trained to do so.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED!
Do not operate this
freezer unless it is properly grounded and all service
panels and access doors are restrained with screws.
Failure to do so can result in severe personal injury
from electrical shock!
S
DO NOT
attempt any repairs unless the
main power supply to the freezer has been
disconnected.
S
DO NOT
operate the freezer with larger
fuses than specified on the data label.
S
Stationary appliances which are not
equipped with a power cord and plug or
other device to disconnect the appliance
from the power source, must have an
all-pole disconnecting device with a contact
gap of at least 3 mm installed in the external
installation.
S
Appliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected, not used for long
periods, or during initial installation, shall
have protective devices such as a GFI to
protect against the leakage of current and
be installed by authorized personnel to the
local codes.
S
Supply cords used with this unit shall be
oil-resistant, sheathed, flexible cable, not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomer-sheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting at the terminals, and
protect the insulation of the conductors from
abrasion.
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
S
Cord Connected Units:
Only Taylor
authorized service technicians may install a
plug on this unit.
Failure to follow these instructions may result in
electrocution or damage to the machine.
Note:
This unit is provided with an equipotential
grounding lug that is to be properly attached to
either the rear of the frame or the underside of the
base pan near the entry hole for incoming power, by
the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021
of IEC 604171) on both the removable panel and
the equipment's frame, as well as on the diagram.
DO NOT
remove the freezer door or any
internal operating parts (examples: beater, scraper
blades, etc.) unless all control switches are in the
OFF position. Failure to follow these instructions
may result in severe personal injury from hazardous
moving parts.
Содержание C723
Страница 2: ......
Страница 39: ...35 Model C723 Controls Systems and Operations 140519 C723 Control Overview Figure 72 ...
Страница 41: ...37 Model C723 Controls Systems and Operations 130409 Refrigeration Schematic Figure 73 ...
Страница 52: ...48 Troubleshooting Model C723 Notes ...
Страница 55: ...51 Model C723 Parts Notes ...
Страница 56: ...52 Parts Model C723 150603 Model C723 Exploded View Figure 74 ...
Страница 59: ...55 Model C723 Parts 140519 Model C723 Operator Parts Figure 75 ...