8
Introduction
Model C723
131028
THIS UNIT HAS MANY SHARP EDGES
THAT CAN CAUSE SEVERE INJURIES.
Examples:
S
scraper blades
S
condenser fins
S
cup/cone dispenser (if applicable)
Electrical Connections
In the United States, this equipment is
intended to be installed in accordance with the
National Electrical Code (NEC), ANSI/NFPA
701987. The purpose of the NEC code is the
practical safeguarding of persons and property from
hazards arising from the use of electricity. This code
contains provisions considered necessary for safety.
In all other areas of the world, equipment should be
installed in accordance with the existing local codes.
Please contact your local authorities.
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the unit
for branch circuit overcurrent protection or fuse,
circuit ampacity, and other electrical specifications.
Refer to the wiring diagram provided inside the
electrical box for proper power connections.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
Note:
This unit is provided with an equipotential
grounding lug that is to be properly attached to
either the rear of the frame or the underside of the
base pan near the entry hole for incoming power, by
the authorized installer. The installation location is
marked by the equipotential bonding symbol (5021
of IEC 604171) on both the removable panel and
the equipment's frame, as well as on the diagram.
S
DO NOT
operate the freezer with larger
fuses than specified on the data label.
S
Stationary appliances which are not
equipped with a power cord and a plug or
another device to disconnect the appliance
from the power source must have an allpole
disconnecting device with a contact gap of
at least 3 mm installed in the external
installation.
S
Appliances that are permanently connected
to fixed wiring and for which leakage
currents may exceed 10 mA, particularly
when disconnected, not used for long
periods, or during initial installation, shall
have protective devices such as a GFI to
protect against the leakage of current and
be installed by authorized personnel to the
local codes.
S
Supply cords used with this unit shall be
oilresistant, sheathed, flexible cable, not
lighter than ordinary polychloroprene or
other equivalent synthetic
elastomersheathed cord (Code designation
60245 IEC 57) installed with the proper cord
anchorage to relieve conductors from strain,
including twisting at the terminals, and
protect the insulation of the conductors from
abrasion.
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
Failure to follow these instructions may result in
electrocution or equipment damage.
Содержание C723
Страница 2: ......
Страница 39: ...35 Model C723 Controls Systems and Operations 140519 C723 Control Overview Figure 72 ...
Страница 41: ...37 Model C723 Controls Systems and Operations 130409 Refrigeration Schematic Figure 73 ...
Страница 52: ...48 Troubleshooting Model C723 Notes ...
Страница 55: ...51 Model C723 Parts Notes ...
Страница 56: ...52 Parts Model C723 150603 Model C723 Exploded View Figure 74 ...
Страница 59: ...55 Model C723 Parts 140519 Model C723 Operator Parts Figure 75 ...