23
Model C723
Controls, Systems and Operations
Service Menu
______________________________
The Service Menu option allows authorized, trained
service technicians to access and modify critical
operating parameters for the machine. The access
code for the Service Menu is:
5 2 3 1
.
Service Menu Options
The Service Menu screen includes the following
options which are also displayed in the Manager's
Menu. (See page 18.)
EXIT FROM MENU
SERVINGS COUNTER
SET CLOCK
AUTO START TIME
STANDBY MODE
MIX LEVEL AUDIBLE
FAULT DESCRIPTION
FAULT HISTORY
LOCKOUT HISTORY
SYSTEM INFORMATION
CURRENT CONDITIONS
NET SERVICE PIN
The Service Menu screen also includes the following
options which can only be accessed through the
Service Menu:
TEMPERATURE SCALE
STANDBY TEMP
HOPPER TEMP
VISCOSITY SETTING
COMPRESSOR CYCLE TIME
COMPRESSOR ON DELAY
BEATER OFF DELAY
MIX PUMP OFF DELAY
EDIT UNIT ID
SELECT LANGUAGE
MANUAL CONTROL
SOFTWARE UPDATE
RESET TO DEFAULTS
Temperature Scale
This option allows the service technician to choose
the scale in which the machine will display all
temperatures. (See Figure 37.)
TEMPERATURE SCALE
FAHRENHEIT
>
Fahrenheit
Celsius
Figure 37
Pressing the UP arrow key moves the arrow to
Fahrenheit. Pressing the DOWN arrow key will
move the arrow to Celsius. Pressing the SEL key
with the arrow next to the appropriate option will
select this option and return to the Service Menu
screen.
Standby Temp
This option allows the service technician to adjust
the freezing cylinder temperature at which the
compressor will turn on in STANDBY. The Left/Right
choice screen is displayed upon selecting this
option. (See Figure 38.)
STANDBY TEMP
LEFT
RIGHT
>
Exit
Figure 38
Pressing the UP or DOWN arrow key moves the
arrow to “Left”, “Right”, or “Exit”. Press the SEL key
to choose the appropriate option. Selecting “Left” or
“Right” displays a second screen which allows the
technician to set the Standby temperature for that
side. (See Figure 39.)
STANDBY TEMP
CUT IN AT
:
39.0
CURRENT :
39.0
>
Next
Figure 39
Содержание C723
Страница 2: ......
Страница 39: ...35 Model C723 Controls Systems and Operations 140519 C723 Control Overview Figure 72 ...
Страница 41: ...37 Model C723 Controls Systems and Operations 130409 Refrigeration Schematic Figure 73 ...
Страница 52: ...48 Troubleshooting Model C723 Notes ...
Страница 55: ...51 Model C723 Parts Notes ...
Страница 56: ...52 Parts Model C723 150603 Model C723 Exploded View Figure 74 ...
Страница 59: ...55 Model C723 Parts 140519 Model C723 Operator Parts Figure 75 ...