4.4.3 Lubricant settings
4.4.3.1 Lubricant pulse
Option:
on / off
You can set the time from
0,1 to 3,0 seconds
.
4.4.3.2 Air pulse
Option:
on / off
You can set the time from
0,2 to 3,0 seconds
. Air pulse starts with the
lubrication pulse.
4.4.3.3 Air cleaning pulse
Option:
on / off
You can set the time from
0,3 to 3,0 seconds
. The impulse start takes
place when the processing is finished.
4.4.4 Motor settings
4.4.4.1 Rotating direction
Option:
right / left
(right / left hand thread)
4.4.4.2 Reverse speed
Option:
20% to 1000%
rpm is always limited to the minimum or maximum rpm.
4.4.4.3 Release height
Option:
on / off
You can set a height (of
5 mm to maximal travel
) above the workpiece
zero point. The release height is a virtual end position at which the
machine can already be restarted.
(When the enabling height is reached, output X367/3 is set to high).