34
4.4.2 Processing types
The types of processing can only be set to „
on
“. The previous setting is set to „
off
“" by
selecting a different startup setting to „
on
“.
4.4.2.1 Threading blind hole
Option:
on
You can set chip breaker settings and reversions.
4.4.2.1.1 Chip breaking
Option:
off / on
You can set the following values after power on:
-
first chip breaking
(first chip breaking depth in mm)
-
interval
(interval depth in mm)
-
chip clearance depth
(chip break angle or depth to the
workpiece zero point, which should be
turned back by chip breaking.)
4.4.2.1.2 Reversions
Option:
on / off
Option:
3 – 15
(maximum number of reversing)
4.4.2.2 Threading through hole
Option:
on
4.4.2.3 Thread recutting
Option:
on
You can adjust the torque reduction during the lead-in chamfer.
(
10 – 90%
).
4.4.2.4 Thread forming
Option:
on
4.4.2.5 Insert threaded bushing
Option:
on
You can select the shutdown parameters:
Option:
torque stop parameter / depth stop parameter
4.4.2.6 Insert bolt
Option:
on
You can select the shutdown parameters:
Option:
torque stop parameter / depth stop parameter
4.4.2.7 Thread gauging
Option:
on
You can set a torque elevation for the return stroke.
(
10 – 4000%
)