Limescale also acts like this on the pipe in which the thermostat and temperature fuse sensors are located, causing the
real temperature in the heater to be higher than the adjusted temperature. For this reason it is necessary to remove
limescale once every two years at least, or more often. For limescale removal, no acid-based substances should be used.
The heater is connected to 230 V AC, a voltage value dangerous to life. In the event of non-
professional intervention a fatal electrical accident can result. Trust your servicing specialist to
perform boiler cleaning and anode rod replacement.
1 . SERVICE
4
Tatramat brand water heaters are designed and assembled with extraordinary care. They leave the manufacturing plant
after passing an entire series of laboratory tests. If, in spite of this a failure appears to shut down the heater's electric
feeder, stop the water supply and contact the nearest service centre.
33
Only an employee trained by the manufacturer can perform warranty service and repairs. It is
dangerous for any other person to tamper with the heater's interior.
1 .
5 POSSIBLE FAULTS AND FAILURE CAUSES
Water is cold
Water is cold
Lukewarm water (does not
correspond to temperature set on
thermostat)
water heating takes a long time
water drips steadily from
the safety valve
signal lamp is on
signal lamp is off
signal lamp is on
signal lamp is on
signal lamp is off
low thermostat temperature
heating element failure
electric supply missingoutside heater
thermostat failure
electric supply switched
off by thermal fuse
thermostat breakdown
heating element covered
by limescale
high water input pressure
safety valve breakdown
By observing the instructions given in the manual herein and with product correct installation, operation and maintenance
we can guarantee that the product will maintain all the technical properties specified by the corresponding technical
conditions throughout its life time. If any defect occurs with the product that is not caused by the user or by an unavoidable
incident (such as damage caused by a disaster) during the warranty period, the client's product will be repaired free of
charge. The product replacement or withdrawal from of sales agreement is governed by the regulations of the Civil Code.
The product warranty term is granted to the final client beginning upon the sales day (or from the commissioning day) for a
period of:
Warranty validity:
The heater manufacturer does not provide a guarantee for damage caused by incorrect installation and connection or by
incorrect operation or maintenance.
5 years for an enamel boiler
24 months for all other parts and product accessories
-
-
1 .
6 WARRANTY
The warranty term is prolonged by the time necessary for servicing, if any, performed during the warranty term.
Warranty certificate filled in correctly, containing the sales date, signature, shop stamp or indicating the
installation date, signature and stamp of the agency shop on heater commissioning (on client's invoice)
carefully preserved bill/invoice, delivery list or other proof of purchase
-
-
Warranty application conditions:
English
The manufacturer does not take any responsibility for problems caused by poor water quality or
water hardness. Limescale removal is not a subject of warranty repair.
Содержание EOV 81
Страница 54: ...20 T ELOV x 1 LOVK x 1 LOVK 120 LOVK 150 ELOV 200 LOVK 200 7 4 6 54 5 0 6 LOVK x 1 1 2 3 4 5 6 7 8 9 10 K 5 6...
Страница 57: ...230 1 4 57 1 5 5 24 18...
Страница 58: ...58 1 2 3 19...
Страница 60: ...20 T ELOV x 1 LOVK x 1 LOVK 120 6 LOVK 150 ELOV 200 LOVK 200 7 4 60 5 0 6 LOVK x 1 1 2 3 4 5 6 7 8 9 10 K 5 6...
Страница 63: ...230 14 I 63 15 5 24 1 6...
Страница 64: ...64 1 2 3 17...