APX-03 Keypad & Proximity Reader Wiring Details
Fig.3 - Wiring detail for Electric Lock with Current Draw 1amp or over
EG: Two Magnetic Locks including Exit Button and Call Point
N/C
COM
N/O
Com N/O
Exit Button
OK
OK
1
1
2
2
3
3
FUN
FUN
4
4
5
5
6
6
7
7
8
8
9
9
CLR
CLR
0
0
EN
MENU
MENU
F
U
S
E
N E L
O/P +
O/P -
Regulated 12v DC Power Supply
(Min 2amp Rated)
Fused Spur
Capacitor
474J 100JS
APX03 Keypad/Reader
Black - Negative input
Red - Positive input
Blue - Ground
White - RQE
Yellow - Relay 1 Common
Brown - Relay 1 Norm. Open
Green - Relay 1 Norm. Closed
Note: Violet, Orange and
Grey wires are not used
+
-
Magnetic Locks 12v DC
Com N/C
Emergency
Call Point
Volt-Free Relay
+
-
Note: Linking wiring from
one magnet to the other
will affect Holding force.
Note: This wiring method can also be
used for Shear Magnets or Solenoid Bolts
OK
OK
1
1
2
2
3
3
FUN
FUN
4
4
5
5
6
6
7
7
8
8
9
9
CLR
CLR
0
0
EN
MENU
MENU
+
-
12v DC
Bell / Sounder
(Max 100mA)
F
U
S
E
N E L
O/P +
O/P -
Regulated 12v DC Power Supply (Min 1amp)
Fused Spur
Fig.4 - Wiring detail for Connection of a 12v DC Bell or Sounder
Grey - Relay 2 Normally open
Orange - Relay 2 Common
Red - Positive Input
Black - Negative Input
Link Orange wire
to Red wire
3
Web: www.tatecolson.co.uk E-mail:[email protected] Tel: 01704-502801 Fax: 01704-502810
Remember to link the
Yellow wire to the
Red wire
+
-