6 − Recording
0
TASCAM SS-R1
Sync Record operation
When you put the SS-R1 in record-ready condition with
the Sync Record function on, recording will automatically
start or stop according to the level of the input source.
When a signal higher than the sync level is input,
recording will begin automatically.
However, recording will not begin even if input is
detected unless there has been at least one second in
which the signal was below the sync level after enter-
ing the record-ready state.
Start of recording
Level
Time
SYNC LEVEL
NOTE
The above explanation is for the case when the
DELAY setting is “0” (the default setting). By changing
the DELAY setting, you can change the “record start”
point.
While recording, if the input signal stays below
the sync level for the duration specified by STOP
TIME (default: 5 seconds), the SS-R1 will auto-
matically switch to the record-ready condition.
SYNC LEVEL
STOP TIME
REC ready
Time
Level
NOTE
If you set the STOP TIME to INF, the record-pause
state will not be entered even though the input signal
falls below the sync level.
•
•
To defeat Sync Record, press the remote’s
SYNC
REC
key.
When the sync level is too high:
If the sync level setting is too high, you may have
problems such as failing to capture the beginning of
a song that begins with a low volume.
SYNC LEVEL
Level
This part of the track
may not be recorded
Time
Recording starts
If the sync level is too low:
Sync recording will not begin if the source you’
re recording has a high noise level, so that the sync
level is exceeded immediately when you enter the
record-ready state.
Level
SYNC LEVEL
Time
Noise is higher
than threshold
Start of track is not registered
•
•
•