![Tascam SS-CDR250N Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/tascam/ss-cdr250n/ss-cdr250n_owners-manual_3855547102.webp)
102
TASCAM SS-CDR250N / SS-R250N
15– Using the Remote Control Connectors
Using the RS-232C connector
Using the RS-232C connector (9-pin D-sub RS-232C standard)
on the back of the unit, this unit can be operated by a computer
or other external device by serial control. In addition, flash start-
ing by remote control is possible if a TASCAM RC-SS150 (sold
separately) is connected.
Select
RS-232C
on the
REMOTE
page to open the
RS-232C
screen.
(See “Menu operation procedures” on page 22.)
Setting the transmission speed (baud rate)
Select
BAUD RATE
, and set the transmission speed (baud rate).
Options:
4800bps
,
9600bps
,
19200bps
,
38400bps
,
57600bps
(default)
Setting the parity bit
Select
PARITY BIT
, and set whether or not there is a parity bit.
Options:
NONE
(none, default value),
EVEN
(even),
ODD
(odd)
Setting the stop bit
Select
STOP BIT
, and set the stop bit.
Options:
1
(default),
2
Set the data length
Select
DATA LENGTH
, and set the data length.
Options:
7bit
,
8bit
(default)
NOTE
i
The 9 pin of this unit's RS-232C connector is used to supply
12V power to the TASCAM RC-SS150 Do not use it to supply
power to any other device. The 9 pin of ordinary computer
RS-232C connectors is unused, so commercially-available RS-
232C cables can be used for connection.
i
For information about this unit's RS-232C command protocol,
please contact the TASCAM customer support service.
Using a footswitch (TASCAM RC-3F)
You can use a TASCAM RC-3F footswitch (sold separately) con-
nected to the REMOTE jack on the front of this unit to control it.
TASCAM RC-3F (sold separately)
Setting up the footswitch
1.
Select
RC-3F MODE
on the
REMOTE
page to open the
RC-
3F MODE
screen. (See “Menu operation procedures” on page
2.
Select one of the three pedal assignment modes.
Option
Meaning
MODE1
(default)
This mode is optimal for recording min-
utes of meetings, for example.
MODE2
This mode provides basic transport re-
mote control.
MODE3
Use this mode for the pitch control func-
tion.
3.
Confirm the setting and return to the Menu Screen.
Using the footswitch
Press the pedals of the footswitch to use the operations assigned
to them by the
RC-3F MODE
item.
Footswitch pedal assignments
MODE
Footswitch
L (press)
C (press)
R (press)
L (press and
hold)
C (release)
R (press and
hold)
1
.
PLAY
/
m
PAUSE/STOP
,
2
.
PLAY/PAUSE
/
m
---
,
3
PITCH (−)
1% incre-
ments
PLAY/PAUSE
PITCH (+)
1% incre-
ments
---
---
---