Advanced Operations
En-65
Adjusting the Volume for Zone 2
■
Operating on the remote controller
■
Operating on the AV receiver
Muting Zone 2
■
Operating on the remote controller
Tip
• To unmute, press
ZONE2
followed by
MUTING
again. Zone can
also be unmuted by adjusting the volume.
Adjusting the Tone and Balance of Zone 2
Note
• Only analog input sources are output from the
ZONE 2
PRE/LINE OUT
jacks. Digital input sources are not output. If no
sound is heard when an input source is selected, verify that the
source is connected to an analog input.
• You cannot select different AM or FM radio stations for your
main room and Zone 2. The same AM/FM radio station will be
heard in each room. Namely, if you have selected an FM station
for the main room, that station will also be output in Zone 2.
• When you have selected
NET
or
USB
as input selector, the last
selector selected will be set for Main room and Zone 2.
• When Zone 2 is activated and its input selector is selected, the
power consumption of standby mode slightly increases.
• While Zone 2 is on,
u
functions will not work.
• When setting the AV receiver to standby mode while Zone 2 is
active, the
Z2
indicator is dimly lit.
• Activating Zone 2 in the main room when the listening mode is
set to Pure Audio (
European models
) will automatically switch
it to Direct.
• The Zone 2 level, balance, and tone functions have no effect on
the
ZONE 2 PRE/LINE OUT
jacks when the “
Zone 2 Out
”
setting is set to “
Fixed
” (
➔
page 60
).
The 12V triggers A, B, and C can be used to turn on 12V
trigger-capable components automatically when they are
selected as the input source. The triggers can be set so that
they activate themselves once a connected component is
selected as the input source for the main room, Zone 2 or
any combination of rooms. When triggered, the output
from a
12V TRIGGER OUT
goes high (+12 volts and
150 milliamperes max. at
12V TRIGGER OUT A
;
+12 volts and 25 milliamperes max. at
12V TRIGGER
OUT B
and
C
).
See “12V Trigger A/B/C Setup” (
➔
page 59
).
Hookup
• Use a miniplug cable to connect the AV receiver’s
12V
TRIGGER OUT A
,
B
, or
C
jack to the 12 V trigger
input of a connected component.
1
Press
ZONE2
.
2
Use
VOL
q
/
w
.
1
Press
ZONE 2
(the Z2 indicator on the AV
receiver’s display flashes).
2
Use
MASTER VOLUME
control within 8 seconds.
1
Press
ZONE2
followed by
MUTING
.
1
On the AV receiver, press
ZONE 2
.
2
Press the AV receiver’s
TONE
repeatedly to select
“Bass”, “Treble” or “Balance”.
3
Use
–/+
to adjust the bass, treble or balance.
• You can boost or cut the bass or treble from –10 dB
to +10 dB in 2 dB steps.
• You can adjust the balance from 0 in the center to
+10 dB to the right or +10 dB to the left in 2 dB
steps.
Using the 12V Triggers