DM-3200 Release Notes
TASCAM DM-3200 Release Notes V1.50
1
This section explains how to make a cascade connection
between two DM-3200s that are running Version 1.20.
1 Using the TASCAM cascade cable (PW-1000CS –
sold separately), connect the CASCADE ports of the
two DM-3200.
WARNING
Only use the special TASCAM cascade cable. Use of
any other type of cable may result in damage to the
equipment.
2 Set one of the DM-3200 units to be the cascade
master, and the other the cascade slave.
To set the master and slave, display the
DIGITAL
screen
using the
DIGITAL
key in the
SCREEN MODE/NUMERIC
ENTRY
section, and use the
POD 3
key (or continue pressing
the
DIGITAL
key) to display the
CASCADE
sub-screen. Set
the
ID
of one of the units to
MASTER
, and the other to
SLAVE
.
Figure 13: DIGITAL>CASCADE screen
NOTE
Set the unit ID while the ON/OFF set-up is
OFF
. You
cannot change the ID set-up while it is
ON
.
3 Turn the ON/OFF setting on the
CASCADE
sub-screen of the cascade master to
ON
.
Move the cursor to the
ON/OFF
button and press the
ENTER
key. A confirmation screen will come up. Check
the setting and press the
ENTER
key again to confirm.
NOTE
ON/OFF status cannot be changed while the timecode
is running.
4 When a cascade connection is established, a pop-up
message “
Cascade connection established
” will be
displayed. Press the
ENTER
key.
NOTE
If a cascade connection was not properly established,
a pop-up message “Cascade Slave not found. Cascade
connection not established” will be displayed.
Making a cascade connection