Solo Innova Instructions 1-800-782-9927 Version 01-18
Tarm Biomass · 4 Britton Lane · Lyme, NH 03768
The boiler must be installed with the
minimum installation clearances
to combustible materials out-
lined below. Clearances may only be reduced by means approved by the regulatory authorities.
Clearances to Combustibles
Measurement
Minimum Distance
Notes
A-Backwall to Appliance
21”
Minimum Distance to Allow Clearance for Blower
Maintenance.
B-Sidewall to Appliance
12”
Minimum Distance
C-Sidewall to Appliance
21”
Minimum Distance on Left Side to Allow Clearance
for Cleaning, and Maintenance, and Easy Removal of
Blower.
D-Front of Appliance
36”
Required Distance for Cleaning the Boiler.
E-Ceiling to Appliance
24”
Required Distance for Cleaning the Boiler.
F-Combustibles to Pipe
18”
Minimum Distance
Boiler Installation & Start-up > Planning
Page 10
CAUTION
DO NOT INSTALL THIS BOILER IN A MOBILE HOME.
There is no safe way this boiler
can be installed inside a mobile home.
☼
A
B
C
F
B
D
E