06
7.2) Test the automatic transmission range:
If when the ignition is turned on, the alarm sounds 1 BEEP, it is indicated that the
battery voltage of the TR2-P control is low and will need to be replaced as soon as
possible.
Battery Replacement Notice
- The LED will flash every 2 seconds:
- To cancel, press any key on the controller.
Activate TR2-P control RANGE test
- Hold down the Off and Auxiliary keys simultaneously;
- Release after the LED goes out;
It is used to test the automatic transmission range of the Presence function on the TR2-P control.With
the automatic transmission of the presence function activated in the control and the function
activated in the alarm central, hold the off and auxiliary keys pressed until the LED goes out. After
releasing the keys, the LED will flash every 2 seconds, on each flash,the alarm will respond with a BEEP,
informing that it has received the transmission. Move the TR2-P control away from the vehicle until the
control panel stops responding. To cancel, press any key on the controller.
Operation:
Attention: The Presence Lock function will only be activated with all vehicle doors closed.
8) Lock by Secret Button -
required to be enabled by master.
ATTENTION: In this case, it will not be possible to cancel the triggering by the control.
Operation:
With the ignition on and the doors closed, press the master key for 1 second. Otherwise, Secret Button
Lock will be enabled. After the programmed time, (according to the Beep 9 setting), the ultrasound
LED starts flashing, the audio will be turned off, the siren and turn signals will go off, 20 secondsafter
that ,l the engine will start failing until it is definitively blocked. To cancel the lock, press the master.
8.1) Valet Function (
Secret Button Lock only
)
the Master pressed for 3 seconds. The LED of the ultrasound
operation, switch the ignition on with the door closed and
will flash 3 times confirming activation.
Operation:
It is used to leave the vehicle in a parking lot, for example, without the need to indicate to the driver the
location of the Master (Secret Button).
With the door closed, turn off the ignition and hold
press the Master for 1 second.
To cancel the valet function and return to normal
+ +
IGNITION
OFF
ON
START
OFF
MASTER
CLOSED
DOOR
3 Seconds
- Hold the master pressed until beep 8.
Enable Secret Button Lock Function
- With the door open, turn the ignition on.
2 Beeps
=Presence Function
OFF
- The alarm will respond informing:
1 Beep
= Presence Function
ON
+ +
IGNITION
ON
START
OFF
MASTER
DOOR OPEN
+
Configure
1X Enable
2X Disable
Select the Beep 8 function
To change, press the Master key , 1x once to Enable or 2x twice to Disable.
After turning off the ignition, the alarm will confirm the new setting with beeps.
Содержание Tarsafe TW20 G4