7.1) Test Presence Function:

 - The LED will flash informing:
        1 flash= PresenceTransmission 

ON

        2 flashes= PresenceTransmission 

OFF

 - Hold the Power and Auxiliary keys pressed;
 - Release after the LED goes out;

Disable the Presence Function on the TR2-P control

Operation:

It is not necessary to move the control away from the vehicle, to test the lock, just disable the automatic 
transmission of the TR2-P control, turn  the ignition on , close the doors and wait.

7) Lock Function by Presence/ Distancing

  - Release after the LED goes out;

Activate the Presence Function on the TR2-P control

     1 flash= Presence Transmission 

ON

 - Hold down the Power and Auxiliary keys;

  - The LED will flash informing:

     2 flashes= PresenceTransmission 

OFF

Operation:

With the ignition on and doors closed, pulling the TR2-P control away from the vehicle automatically 
activates the distancing lock. After the programmed time (Beep 9 of the configuration by the master), 
the ultrasound LED starts flashing the audio will be turned off, the siren and turn signals will go off, ther 
10 seconds, the engine will start failing until it is definitively blocked. To cancel the lock, bring the TR2-P 
control closer to the vehicle and wait for the automatic transmission or press the end key.

Activate Presence Function in the Alarm Central

- Hold the master pressed until beep 7.

    

2 Beeps

 =Presence Function OFF

    1 Beep 

  = Presence Function ON

- With the door open, turn the ignition on.

- To change, press 1x (once) to Enable or 2 x (twice) to Disable.After turning off the 
ignition, the alarm will confirm the new setting with beeps.

- The alarm will respond informing:

Set Time for  Locking, 1, 2 or 3 minutes

- With the door open, turn the ignition on.

    

2 Beeps

 = Lock in 2 Minutes

- Hold the master pressed until beep 9.
- The alarm will respond informing:

   

 3 Beeps

 = Lock  in3 Minutes

    

1 Beep 

  = Lock in 1 Minute

To change, press the Master key the number of times referring to the desired 
time. Each time you  press the Master, the alarm confirms with 1 beep.After 
turning the ignition off , the alarm will confirm the new setting with beeps.

+

MASTER

Attention: Function canceled from the factory, must be enabled by Beep 7.
In G4 alarms it is possible to enable the Presence Functions   by Beep 7 and the Lock by 
Secret Button Beep 8.

+ +

IGNITION

ON

START

OFF

MASTER

DOOR OPEN

+

Configure

   1X Enable

   2X Disable

Select the Beep 7 function

+ +

IGNITION

ON

START

OFF

MASTER

DOOR OPEN

+

Configure

1X = 1 minute
2X = 2 minutes
3X = 3 minutes

Select the Beep 9 function

TR2-P Control Required

05

Содержание Tarsafe TW20 G4

Страница 1: ...MANUAL AUTOMOTIVE ALARM TW20 ...

Страница 2: ...stallation of this product must be done by a specialized professional Carefully clean the location where the ultrasound sensors and master switchwillbeplaced 1 Before Starting ATTENTION We recommend the complete reading of this manual before proceeding with the installation of this product 3 Composition BASICALARM OPERATION Whenturning on the alarm byremotecontrol if the vehicle has audio equipmen...

Страница 3: ...19 ATTENTION Functiononlyexistsin controls manufacturedfromJune 2019 4 Remote Controls Ÿ Operating Frequency 433 92MHz Ÿ Anti Cloning Technology Hopping Code Ÿ Anti Jammer Transmission System Ÿ 1 3V Battery CR 2032 LITHIUM Images for illustrative purposes only and may differ from the real image See item 3 to check which remote control belongs to which Alarm model Anycontrolmodelcanbepurchasedsepara...

Страница 4: ...eOpenDoor Item9 1 2flashesonturnsignals 2sirenbeeps Note 4flashesontheturnsignals 4beeps indicate that there was a trigger when the alarmwasactivated Item12 1 2flashesonturnsignals Note 4 flashes on the turn signals indicate that there was a trigger when thealarmwasactivated Item12 1 Press for2seconds with alarmon 6 Panic 1 Long beep confirms ultrasound cancellation and window close Ultrasound operates...

Страница 5: ... FACTORY RESET 12 ULTRASOUND SENSITIVITY ADJUSTMENT 10 AUTOMATIC UNLOCK 5 3 1 1 1 3 See item 4 item 9 3 item 9 4 item 7 item 8 item 11 1 beep ENALE 2 beeps DISABLE 1 beep ENABLE 2 beeps DISABLE 1 beep starts in 1 minuto 2 beeps starts in 2 minutos 3 beeps starts in 3 minutos 1 beep ENABLE 2 beeps DISABLE Press and release the master until you hear the desired ring 1 beep ENABLE 2 beeps DISABLE 1 b...

Страница 6: ...celthelock bringtheTR2 P controlclosertothevehicleandwaitfortheautomatictransmissionorpresstheendkey ActivatePresenceFunctionintheAlarmCentral Holdthemasterpresseduntilbeep7 2Beeps PresenceFunctionOFF 1Beep PresenceFunctionON Withthedooropen turntheignitionon To change press 1x once to Enable or 2 x twice to Disable After turning off the ignition thealarmwillconfirmthenewsettingwithbeeps Thealarmwil...

Страница 7: ...e itwillnotbepossibletocancelthetriggeringbythecontrol Operation With the ignition on and the doors closed press the master key for 1 second Otherwise Secret Button Lock will be enabled After the programmed time according to the Beep 9 setting the ultrasound LED starts flashing the audio will be turned off the siren and turn signals will go off 20 secondsafter that ltheenginewillstartfailinguntilitis...

Страница 8: ...n for TW20 RF model 07 08 Fix on the vehicle windshield 10cm below the roof Left Side Receiver Right Side Transmitter 13 Black 6 Yellow 7 Red 8 Green negative door switch Gray Gray ENGINE LOCK MAX 20A Illustrative images 16 Purple Audio Equipment ACC audio equipment Max 200mA 15 Black White 14 Black 12 Blue Ignition 11 Red Black UNLOCK Output to Power Window Closing Modules 9 Brown According to in...

Страница 9: ... the alarm back on If it s not solved the alarm will cancel the door monitoring The rest will continue operating normally If the problem persists look for a specialized service to repair the door switch 2 SHUTDOWN TRIGGERING LIMITER In case of violation the alarm will trigger the SIREN and flash the TURN SIGNALS for 45 seconds 5 seconds later it will go back to monitoring the sensors After 4 trigge...

Страница 10: ... NEGATIVE alarm signal 2 0 0 m A i n t o N E G AT I V E of higher power 30 85 87 AlarmWire Negtive Output 86 12V Battery Positive 11 VW G6 and G7 Power Window and Door Connections 3 Beeps FIAT 5 Beeps VW UP The alarm will respond informing 1 Beep Universal 2 Beeps VW G5 Hold the master pressed until beep 11 6 Beeps MOBI Signal for window Electric Lock activation Setup With the door open turn the i...

Страница 11: ...ated above the acceleratorpedal DONOTconnectRed BlackandRed Yellow lockandunlock wires Toopenthewindows holdthecontroloffbuttonpressedwiththealarmoff To open the Trunk connect the Gray wire from the alarm to the Brown Red wire pin 34 from theoriginalcentrallocatedabovethefusebox NORESISTORNEEDED 11 5VWUP OnlyLOCKandUNLOCK Functions lock unlock closeandopenthewindows 11 4 VW G6 and G7 mode Gol Saveir...

Страница 12: ...elect Beep 12 function 12 Click 1 Once 2 Twice 3 Times 4 Times 5 Times Alarm Response Sensor Sensitivity 20 10 Factory standard 10 20 1 Beep 2 Beeps 3 Beeps 4 Beeps 5 Beeps Decrease Increase LED FLASHING NORMALLY Alarm on LED FLASHES 2X Alarm on with cancelled ultrasound sensor 2 consecutive flashes ultrasound sensor LED FLASHING AFTER TURNING OFF ALARM BY REMOTE CONTROL Indicates which sensor caus...

Страница 13: ...ativesignal whenopen Itisusedtolowerelectricwindowsforexample 4 HeadlightWarningOn Off Whenturning theignitionoff andopeningthedoorwiththeheadlighton thealarmsoundsa longbeep Usingan AuxiliaryRelayisrequired 2 ReadsPositiveswitch 1 ReadsNegativeswitch After 10 seconds with the ignition on the ultrasound LED will be flashing warning that the headlightisoff turningontheheadlight theLEDgoesout To change ...

Страница 14: ... nº274 ZIP19 180 000 Factorytechnicalassistancedepartment E mail service taramps com br Fones 55 18 3266 4050 99749 3391 To change press the Master key the number of times referring to the desired function EachtimeyoupresstheMaster thealarm confirmswith1beep After turningtheignition offthealarmwillconfirmthenewsettingwithbeeps MASTER ProgrammingbyMaster 1Beep Disabled 2Beeps Turnsonthealarmwithoutloc...

Страница 15: ...MN_015377_R03 Fabricado por Manufactured by TARAMPS ELECTRONICS LTDA CNPJ TAX ID 11 273 485 0001 03 R João Silvério 121 Res Manoel Martins Alfredo Marcondes SP Indústria Brasileira Made in Brazil ...

Отзывы: