- Hold the master pressed until beep 12.
1 Beep = Sensitivity
+20%
3 Beeps = Sensitivity
Standard
4 Beeps = Sensitivity
-10%
2 Beeps = Sensitivity
+10%
5 Beeps = Sensitivity
-20%
- With the door open, turn the ignition on.
Set Ultrasound Sensitivity:
--The alarm will respond informing the current setting.
To change, press the Master key the number of times referring to the
desired sensitivity. Each time you press the Master ,the alarm confirms
with 1 beep. After turning the ignition off, the alarm will confirm the new
setting with beeps.
+
MASTER
+
Configure
1X = +20%
2X = +10%
3X = Standard
4X = -10%
5X = -20%
+ +
IGNITION
ON
START
OFF
MASTER
DOOR OPEN
Select Beep 12 function
12
Click
1 Once
2 Twice
3 Times
4 Times
5 Times
Alarm Response
Sensor Sensitivity
+20%
+10%
Factory standard
-10%
-20%
1 Beep
2 Beeps
3 Beeps
4 Beeps
5 Beeps
Decrease
Increase
LED FLASHING NORMALLY
- Alarm on;
LED FLASHES 2X
- Alarm on, with cancelled ultrasound sensor;
- 2 consecutive flashes - ultrasound sensor.
LED FLASHING AFTER TURNING OFF ALARM BY REMOTE CONTROL
- Indicates which
sensor caused the last trigger:
LED ALWAYS ON
- Door, Hood or Trunk open;
- 3 flashes in a sequence- doors, hood or trunk.
LED OFF
- Alarm off;
- 1 flash - ignition.
Attach the sensors to the vehicle's windshield, 10 cm below the
roof. Ultrasound sensors come with digital sensitivity adjustment.
The table follows below:
Change the default setting only if necessary.
12.1) LED FUNCTIONS:
12) G2 Ultrasound Sensors
Содержание Tarsafe TW20 G4
Страница 1: ...MANUAL AUTOMOTIVE ALARM TW20 ...