background image

10

10) Relay Connections

Function

 Closes and opens the power windows, locks and unlocks the doors and opens the 

:

 

trunk.
Window activation signal setting = 

VW G6 / G7, 

.

item 11

To open windows, turn off the alarm and hold down the off button on the control.
To open the trunk  with the alarm off, hold the Auxiliary button pressed.

The  lock,  unlock,  auxiliary  and  audio  equipment  outputs  can  handle  a  maximum  of 
200mA.
If it is necessary to install equipment with a consumption that is higher than 200mA, relays 
must be used.

 ORIGINAL CENTRAL  VW G6 / G7

fuse box

Located above the 

34 - Brown / Red

36 - Brown / Red

11 - Red / Black

3 - Gray

Transform NEGATIVE alarm signal 
 (200mA) into PO12V

Alarm Wire

85

30

+12V

87

86

12V

Purple 

Wire

Alarm

Transform POSITIVE alarm signal (AUDIO)
( 2 0 0 m A )   i n t o   P O S I T I V E
+12V of higher power.

85

30

87

+12V

86

Battery

 Negative

Battery

 Negative

+ACC 

Audio equipment

Transform NEGATIVE alarm  signal 
( 2 0 0 m A )   i n t o   N E G A T I V E
of higher power.

30

85

87

Alarm Wire

Negtive Output

86

 +12V

Battery 

Positive

11) VW G6 and G7 Power Window and Door  Connections:

    

3 Beeps

 = FIAT

    

5 Beeps

 = VW UP

.- The alarm will respond informing:
    

1 Beep

   = Universal

    

2 Beeps

 = VW G5

- Hold the master pressed until beep 11

    

6 Beeps

 = MOBI

Signal for window/Electric Lock activation Setup

- With the door open, turn the ignition on.

    

4 Beeps

 = VW G6

To change it, press the Master key  4 times, referring to the VW G6/G7 signal. 
Each  time  you  press  the  Master,  the  alarm  confirms  with  1  beep.  After 
turning the ignition off , the alarm will confirm the new setting with 4 beeps.

+

MASTER

Attention:

 The trunk opening function will only work in vehicles with original electrical trunk 

opening  system.  For  its  perfect  operation,  properly  ground  the  alarm  module.  Some  wire 
colors may change without prior notice from the car   manufacturer. It is important to test 
before making the connections.

+

Configure

1X = Universal
2X = VW G5
3X = FIAT
4X = VW G6
5X = VW UP
6X = MOBI

+ +

IGNITION

ON

START

OFF

MASTER

DOOR OPEN

Select the Beep 11 function

Содержание Tarsafe TW20 G4

Страница 1: ...MANUAL AUTOMOTIVE ALARM TW20 ...

Страница 2: ...stallation of this product must be done by a specialized professional Carefully clean the location where the ultrasound sensors and master switchwillbeplaced 1 Before Starting ATTENTION We recommend the complete reading of this manual before proceeding with the installation of this product 3 Composition BASICALARM OPERATION Whenturning on the alarm byremotecontrol if the vehicle has audio equipmen...

Страница 3: ...19 ATTENTION Functiononlyexistsin controls manufacturedfromJune 2019 4 Remote Controls Ÿ Operating Frequency 433 92MHz Ÿ Anti Cloning Technology Hopping Code Ÿ Anti Jammer Transmission System Ÿ 1 3V Battery CR 2032 LITHIUM Images for illustrative purposes only and may differ from the real image See item 3 to check which remote control belongs to which Alarm model Anycontrolmodelcanbepurchasedsepara...

Страница 4: ...eOpenDoor Item9 1 2flashesonturnsignals 2sirenbeeps Note 4flashesontheturnsignals 4beeps indicate that there was a trigger when the alarmwasactivated Item12 1 2flashesonturnsignals Note 4 flashes on the turn signals indicate that there was a trigger when thealarmwasactivated Item12 1 Press for2seconds with alarmon 6 Panic 1 Long beep confirms ultrasound cancellation and window close Ultrasound operates...

Страница 5: ... FACTORY RESET 12 ULTRASOUND SENSITIVITY ADJUSTMENT 10 AUTOMATIC UNLOCK 5 3 1 1 1 3 See item 4 item 9 3 item 9 4 item 7 item 8 item 11 1 beep ENALE 2 beeps DISABLE 1 beep ENABLE 2 beeps DISABLE 1 beep starts in 1 minuto 2 beeps starts in 2 minutos 3 beeps starts in 3 minutos 1 beep ENABLE 2 beeps DISABLE Press and release the master until you hear the desired ring 1 beep ENABLE 2 beeps DISABLE 1 b...

Страница 6: ...celthelock bringtheTR2 P controlclosertothevehicleandwaitfortheautomatictransmissionorpresstheendkey ActivatePresenceFunctionintheAlarmCentral Holdthemasterpresseduntilbeep7 2Beeps PresenceFunctionOFF 1Beep PresenceFunctionON Withthedooropen turntheignitionon To change press 1x once to Enable or 2 x twice to Disable After turning off the ignition thealarmwillconfirmthenewsettingwithbeeps Thealarmwil...

Страница 7: ...e itwillnotbepossibletocancelthetriggeringbythecontrol Operation With the ignition on and the doors closed press the master key for 1 second Otherwise Secret Button Lock will be enabled After the programmed time according to the Beep 9 setting the ultrasound LED starts flashing the audio will be turned off the siren and turn signals will go off 20 secondsafter that ltheenginewillstartfailinguntilitis...

Страница 8: ...n for TW20 RF model 07 08 Fix on the vehicle windshield 10cm below the roof Left Side Receiver Right Side Transmitter 13 Black 6 Yellow 7 Red 8 Green negative door switch Gray Gray ENGINE LOCK MAX 20A Illustrative images 16 Purple Audio Equipment ACC audio equipment Max 200mA 15 Black White 14 Black 12 Blue Ignition 11 Red Black UNLOCK Output to Power Window Closing Modules 9 Brown According to in...

Страница 9: ... the alarm back on If it s not solved the alarm will cancel the door monitoring The rest will continue operating normally If the problem persists look for a specialized service to repair the door switch 2 SHUTDOWN TRIGGERING LIMITER In case of violation the alarm will trigger the SIREN and flash the TURN SIGNALS for 45 seconds 5 seconds later it will go back to monitoring the sensors After 4 trigge...

Страница 10: ... NEGATIVE alarm signal 2 0 0 m A i n t o N E G AT I V E of higher power 30 85 87 AlarmWire Negtive Output 86 12V Battery Positive 11 VW G6 and G7 Power Window and Door Connections 3 Beeps FIAT 5 Beeps VW UP The alarm will respond informing 1 Beep Universal 2 Beeps VW G5 Hold the master pressed until beep 11 6 Beeps MOBI Signal for window Electric Lock activation Setup With the door open turn the i...

Страница 11: ...ated above the acceleratorpedal DONOTconnectRed BlackandRed Yellow lockandunlock wires Toopenthewindows holdthecontroloffbuttonpressedwiththealarmoff To open the Trunk connect the Gray wire from the alarm to the Brown Red wire pin 34 from theoriginalcentrallocatedabovethefusebox NORESISTORNEEDED 11 5VWUP OnlyLOCKandUNLOCK Functions lock unlock closeandopenthewindows 11 4 VW G6 and G7 mode Gol Saveir...

Страница 12: ...elect Beep 12 function 12 Click 1 Once 2 Twice 3 Times 4 Times 5 Times Alarm Response Sensor Sensitivity 20 10 Factory standard 10 20 1 Beep 2 Beeps 3 Beeps 4 Beeps 5 Beeps Decrease Increase LED FLASHING NORMALLY Alarm on LED FLASHES 2X Alarm on with cancelled ultrasound sensor 2 consecutive flashes ultrasound sensor LED FLASHING AFTER TURNING OFF ALARM BY REMOTE CONTROL Indicates which sensor caus...

Страница 13: ...ativesignal whenopen Itisusedtolowerelectricwindowsforexample 4 HeadlightWarningOn Off Whenturning theignitionoff andopeningthedoorwiththeheadlighton thealarmsoundsa longbeep Usingan AuxiliaryRelayisrequired 2 ReadsPositiveswitch 1 ReadsNegativeswitch After 10 seconds with the ignition on the ultrasound LED will be flashing warning that the headlightisoff turningontheheadlight theLEDgoesout To change ...

Страница 14: ... nº274 ZIP19 180 000 Factorytechnicalassistancedepartment E mail service taramps com br Fones 55 18 3266 4050 99749 3391 To change press the Master key the number of times referring to the desired function EachtimeyoupresstheMaster thealarm confirmswith1beep After turningtheignition offthealarmwillconfirmthenewsettingwithbeeps MASTER ProgrammingbyMaster 1Beep Disabled 2Beeps Turnsonthealarmwithoutloc...

Страница 15: ...MN_015377_R03 Fabricado por Manufactured by TARAMPS ELECTRONICS LTDA CNPJ TAX ID 11 273 485 0001 03 R João Silvério 121 Res Manoel Martins Alfredo Marcondes SP Indústria Brasileira Made in Brazil ...

Отзывы: