BARRIER & STOP (BARR)
Issue : 020913-B
TPUK-GU31X
15
Trouble shooting
Check the system is configured as shown in the recommended configuration then
see possible solutions below. If the problem persists consult Tapflo (UK).
Symptom
Cause
Remedy
Pump failure.
See pump operating manual.
System is
inoperative
Unstable air supply.
Check all connections and air
supply.
Set point is not correct.
Perform set up procedure.
Air supply is not stable.
Fit air pressure regulator.
Pump stops
erratically
Media has changed.
Perform recalibration.
Leaking
interconnections.
Remake or replace interconnections.
Guardian set for
alternative application.
Check function plate position.
Consult Tapflo (UK) Ltd.
Incorrect configuration.
Check all connections against
recommended installation.
Air pressure too low.
Air pressure must be > 1bar higher
than set point.
Guardian
does not
work
Guardian tie rods loose. Check torque is within specification.
Primary diaphragm
breach!
Immediately stop pump, isolate
and perform maintenance.
Poor installation.
Remake interconnections.
MEDIA
EGRESS
Guardian tie rods loose. Check torque is within specification.
Содержание Guardian system Mk3.1
Страница 11: ...BARRIER STOP BARR Issue 020913 B TPUK GU31X 9 BARRIER STOP BARR...
Страница 18: ...BARRIER STOP BARR Issue 020913 B TPUK GU31X 16...
Страница 19: ...DRY RUN STOP DR S Issue 020913 B TPUK GU31X 17 DRY RUN STOP DR S...
Страница 24: ...DRY RUN STOP DR S Issue 020913 B TPUK GU31X 22...
Страница 25: ...DEAD HEAD STOP DH S Issue 020913 B TPUK GU31X 23 DEAD HEAD STOP DH S...
Страница 31: ...DEAD HEAD RESTART DH R Issue 020913 B TPUK GU31X 29 DEAD HEAD RESTART DH R...
Страница 43: ...WARRANTY Issue 020913 B TPUK GU31X 41 Warranty return form Sketch of installation...