BARRIER & STOP (BARR)
Issue : 020913-B
TPUK-GU31X
13
9.
Slowly increase the set point regulator adjustment screw (Fig.GEN-01,
2) (clockwise) until the reset button stops trying to pop out.
10.
Remove the set point pressure.
11.
Press the Reset button and it should remain in the in position
12.
Reapply the set point pressure and the reset button should automatically
extend.
13.
If not repeat steps 6-12.
14.
The calibration is now complete and the system is ready for use.
Calculated
This method of set up is used when the set point pressure is known. The
Guardian’s set point is simply adjusted to a specific pressure using an
external pressure gauge connected to the ‘set point o/p’ connection.
1.
Remove the M5 plug and connect an external pressure gauge to
the ‘set
point O/P’ connection
.
2.
Plug all other open ports, except reset.
3.
Using a flat bladed screwdriver adjust the set point regulator adjustment
screw (Fig.GEN-01, 2) of the Guardian anti-clockwise until it turns freely
4.
Turn the air supply on.
5.
Slowly increase the set point regulator adjustment screw (Fig.GEN-01,
2) (clockwise) until the pressure gauge indicates 0.5 Bar below the
required set point (i.e. 3.0 bar switching = 2.5 bar set).
6.
Turn off the air supply.
7.
Remove the pressure gauge, and re-install M5 plug.
8.
The set up is now complete and the system is ready for use.
Содержание Guardian system Mk3.1
Страница 11: ...BARRIER STOP BARR Issue 020913 B TPUK GU31X 9 BARRIER STOP BARR...
Страница 18: ...BARRIER STOP BARR Issue 020913 B TPUK GU31X 16...
Страница 19: ...DRY RUN STOP DR S Issue 020913 B TPUK GU31X 17 DRY RUN STOP DR S...
Страница 24: ...DRY RUN STOP DR S Issue 020913 B TPUK GU31X 22...
Страница 25: ...DEAD HEAD STOP DH S Issue 020913 B TPUK GU31X 23 DEAD HEAD STOP DH S...
Страница 31: ...DEAD HEAD RESTART DH R Issue 020913 B TPUK GU31X 29 DEAD HEAD RESTART DH R...
Страница 43: ...WARRANTY Issue 020913 B TPUK GU31X 41 Warranty return form Sketch of installation...