WARRANTY 

Issue : 020913-B 

TPUK-GU31X 

   

39 

 
 
 

Warranty 

 
Tapflo UK warrants products under conditions as below for a period of not more than 12 months from installation and 
not more than 24 months from date of manufacture. 
 
1.

 

The following terms and condition apply to the sale of machinery, components and related services and products, 
of Tapflo UK (hereinafter “the products”) 
 

2.

 

Tapflo UK (the manufacturer) warrants that: 

 

a.

 

its products as being free of defects in material, design and workmanship at the time of original purchase; 

b.

 

its products will function in accordance with Tapflo UK operative manuals; Tapflo UK does not guarantee that 

the product will meet the precise needs of the Customer, except for those purposes set out in any invitation to 
tender documents or other documents specifically made available to Tapflo UK before entering into this 
agreement; 

c.

 

high quality materials are used in the construction of the products and that machining and assembly are 

carried out to the highest standards. 
 

Except as expressly stated above, Tapflo UK makes no warranties, express or implied, concerning the products, 
including all warranties of fitness for a particular purpose. 
 

3.

 

This warranty shall not be applicable in circumstances other than defects in material, design, and workmanship. 
In particular warranty shall not cover the following: 
 
a.

 

Periodic checks, maintenance, repair and replacement of parts due to normal wear and tear (seals, O-rings, 

rubber items, bushings, etc..); 

b.

 

Damage to the product resulting from: 

1.

 

Tampering with, abuse or misuse, including but not limited to failure to use the product for its normal 
purposes as stated at the time of purchase or in accordance with Tapflo UK instructions for use and 
maintenance of the product, or the installation or improper ventilation or use of the product in a manner 
inconsistent with the technical or safety standard in force; 

2.

 

Repairs performed by non-skilled personnel or use of non-original Tapflo UK parts 

3.

 

Accidents or any cause beyond the control of Tapflo UK, including but not limited to lightning, water, fire, 
earthquake, and public disturbances, etc.; 
 

4.

 

The warrantee shall cover the replacement or repairing of any parts, which is documentedly faulty due to 
construction or assembling, with new or repaired parts free of charges delivered by Tapflo. Parts subjected to 
normal tear and wear shall not be covered by the warranty. Tapflo shall decide as to whether the defective or 
faulty part shall be replaced or repaired. 
 

5.

 

The warrantee of the products shall be valid for a period in accordance to the current law from the date of 
delivery, under the condition that notice of the alleged defect to the products or parts thereof be given to Tapflo 
UK in written within the mandatory term of 8 days from the discovery. 

 
6.

 

Repair or replacement under the terms of this warranty shall not give a right to an extension to, or a new 
commencement of, the period of warranty. Repair or replacement under the terms of this warranty may be 
fulfilled with functionally equivalent reconditioned units. Tapflo UK qualified personnel shall be solely entitled to 
carry out repair or replacement of faulty parts after careful examination of the pump. Replaced faulty parts or 
components will become the property of Tapflo UK 

 
7.

 

The products are built in accordance with standard CE normative and are tested (where applicable) by Tapflo 
UK. Approval and tests by other control authority are for the customers account. The products shall not be 
considered defective in materials, design or workmanship if they need to be adapted, changed or adjusted to 
conform to national or local technical or safety standards in force in any country other than that for which the unit 
was originally designed and manufactured. This warranty shall not reimburse such adaptations, changes or 
adjustments, or attempt to do so, whether properly performed or not, nor any damage resulting from them, nor 
any adaptation, change or adjustments to upgrade the products from their normal purpose as described in the 
products operative manual without the prior written consent of Tapflo UK 

 
8.

 

Installation, including electric and other connections to utility mains according to Tapflo UK drawings, is for the 
cost and responsibility of the customer, unless otherwise agreed in writing. 

 
9.

 

Tapflo UK will not be liable on any claim, whether in contact, tort, or otherwise, for any indirect, special, 
incidental, or consequential damages, caused to the customer or to third parties, including loss of profits, arising 
by any possible infringement of par. 3 above or by the customer or third parties being in the impossibility of using 
the products. 

 
Notwithstanding the above, Tapflo UK liability to the customer or third parties from any claim, whether in contract, 
tort, or otherwise, shall be limited to the total amount paid by the customer for the product that caused the damages. 

Содержание Guardian system Mk3.1

Страница 1: ...TPUK GU31X _T Operation Maintenance Manual Guardian system Mk3 1 Instructions for the installation start up operation maintenance and repair Spare parts STOP Read this instruction manual carefully be...

Страница 2: ...oint adjustment Operation Trouble shooting 17 Dry run Stop DR S Principle of operation Recommended installation Set point adjustment Operation Trouble shooting 23 Dead head Stop DH S Principle of oper...

Страница 3: ...s group II Protection method Constructional safety Maximum surface temperature 135O C Marking Standards Directives EN13463 1 EN13463 5 The Machinery Directive 2006 42 EC Non Annex IV Machinery Self de...

Страница 4: ...w and the prevention of damage to or destruction of the system or its associate equipment This symbol signals possible danger caused by the presence of electric fields or live wires Receiving inspecti...

Страница 5: ...amage and may cause injury to personnel Health and Safety Systems must be installed according to local and national safety rules The system must be suitable for the application Failure to do so could...

Страница 6: ...ures Fully pneumatic Floating PTFE diaphragm 316L stainless steel PTFE conductive or Aluminum wetted parts Pilot output to control the associate pump Integral reset button Integral visual indicator Pn...

Страница 7: ...ction plate as shown if Fig GEN 01 in conjunction with the associate table below To reconfigure undo the 4x retaining screws and rotate the plate to the correct orientation and refit being careful to...

Страница 8: ...uardian must be adjusted to the correct set point to ensure proper operation Follow the instructions detailed in the application specific sections of this manual Fig GEN 02 1 Guardian Mk 3 1 2 Set poi...

Страница 9: ...ush fit connection into the Reset I P connection Connect a 3 2 NC valve to the reset I P connection Valve could be manual or solenoid operated and only need be a small orifice M5 size valve The reset...

Страница 10: ...facility see Fig GEN 04 Remove the M5 plug and install a 4mm to M5 push fit connection into the Alarm O P connection Fig GEN 04 2 Connect any of the output options as shown in Fig GEN 04 4 5 6 or 7 T...

Страница 11: ...BARRIER STOP BARR Issue 020913 B TPUK GU31X 9 BARRIER STOP BARR...

Страница 12: ...pically no additional system is used to determine if a breach has occurred and the fault goes unnoticed contaminating the media with incompatible materials and eventually the back up diaphragms breach...

Страница 13: ...page 6 Media connection is connected to the barrier void ports The void ports should be linked as shown in Fig BARR 02 4 P2 Air supply is connected to a filtered and regulated compressed air source of...

Страница 14: ...n be started and stopped normally by turning the supply to the Guardian on off however if not or it stops the pump erratically increase the set point regulator clockwise in half turn increments until...

Страница 15: ...int is simply adjusted to a specific pressure using an external pressure gauge connected to the set point o p connection 1 Remove the M5 plug and connect an external pressure gauge to the set point O...

Страница 16: ...aintained before being returned to service Refer to the Maintenance section of this manual for procedures to safely maintain the Guardian Please refer to the pump manual for details on how to safely m...

Страница 17: ...lator Pump stops erratically Media has changed Perform recalibration Leaking interconnections Remake or replace interconnections Guardian set for alternative application Check function plate position...

Страница 18: ...BARRIER STOP BARR Issue 020913 B TPUK GU31X 16...

Страница 19: ...DRY RUN STOP DR S Issue 020913 B TPUK GU31X 17 DRY RUN STOP DR S...

Страница 20: ...luid discharge pressure of the pump changing it s output if the monitored pressure falls below the set point of the Guardian representing a loss of media in the pump suction line stopping the associat...

Страница 21: ...gulated compressed air source Valve O P pilots an external pilot valve sized appropriately for the pumps air inlet such as a Tapflo TPUK BV Alarm O P can be connected to a variety of indicators or plu...

Страница 22: ...uardian anti clockwise until it turns freely 5 Turn on the air supply 6 Slowly increase the set point regulator adjustment screw Fig GEN 01 2 clockwise until the pressure gauge indicates desired press...

Страница 23: ...ect Perform recalibration Air supply is not stable Fit air pressure regulator Media has changed Perform set up procedure Pump stops erratically Leaking interconnections Remake or replace interconnecti...

Страница 24: ...DRY RUN STOP DR S Issue 020913 B TPUK GU31X 22...

Страница 25: ...DEAD HEAD STOP DH S Issue 020913 B TPUK GU31X 23 DEAD HEAD STOP DH S...

Страница 26: ...scharge pressure of the pump changing it s output if the monitored pressure exceeds the set point of the Guardian representing a closed valve or over pressure in the pump discharge line stopping the a...

Страница 27: ...nd regulated compressed air source Valve O P pilots an external pilot valve sized appropriately for the pumps air inlet such as a Tapflo TPUK BV Alarm O P can be connected to a variety of indicators o...

Страница 28: ...a further half turn 7 The Reset button should remain in the in position and the pump can be started and stopped normally by turning the supply to the Guardian on off however if not or it stops the pum...

Страница 29: ...system is ready for use Calculated This method of set up is used when the set point pressure is known The Guardian s set point is simply adjusted to a specific pressure using an external pressure gaug...

Страница 30: ...tom Cause Remedy Pump failure See pump operating manual Unstable air supply Check all connections and air supply System is inoperative Inconsistent pump discharge pressure Fit back pressure device suc...

Страница 31: ...DEAD HEAD RESTART DH R Issue 020913 B TPUK GU31X 29 DEAD HEAD RESTART DH R...

Страница 32: ...changing it s output if the monitored pressure rises to the set point of the Guardian representing a closed valve or over pressure in the pump discharge line stopping the associate pump and automatica...

Страница 33: ...o the discharge pipe work of the pump Air in is connected to a filtered and regulated compressed air source Valve O P is plugged DH R O P pilots an external pilot valve sized appropriately for the pum...

Страница 34: ...be started and stopped normally by turning the supply to the Guardian on off however if not or it stops the pump erratically increase the set point regulator clockwise in half turn increments until th...

Страница 35: ...s known The Guardian s set point is simply adjusted to a specific pressure using an external pressure gauge connected to the set point O P connection 1 Remove the M5 plug and connect an external press...

Страница 36: ...orrect Perform recalibration Air supply is not stable Fit air pressure regulator Media has changed Perform set up procedure Pump stops erratically Leaking interconnections Remake or replace interconne...

Страница 37: ...32mm DD 72mm DW 71mm DB 24mm slot 5x10 ATEX A Earth point Fig SP 01 Connections Port No Description Connection type 12 Reset I P M5 2 Valve O P 4mm push fit 1 Air in 4mm push fit 4 Alarm O P M5 Suppli...

Страница 38: ...sure Absolute Maximum pressure 12 BAR 25 BAR 8 BAR Weight 1100g 1400g 1100g Note Air in must be 1 bar greater than the set point Guardian coding The code details the specifications function and materi...

Страница 39: ...do tie rods and remove air side assembly from the fluid side of the Guardian 2 Inspect the diaphragm surface for damage If the diaphragm is undamaged reassemble the guardian and perform the set up pro...

Страница 40: ...push fit connector 3 PF 4 M5 STUD 9 Set point regulator cover 1 G SPCOVER X 10 Set point regulator screw 1 TPUK 00305 X 4 F SOCCAP M4X30 A2 70 4 F NUT M4 NYLOCK A2 11 Tie rods nuts washers 8 F WASHER...

Страница 41: ...r and wear shall not be covered by the warranty Tapflo shall decide as to whether the defective or faulty part shall be replaced or repaired 5 The warrantee of the products shall be valid for a period...

Страница 42: ...Contact Name Telephone Fax E mail Delivery date Install date System Type Serial No Description of fault Media Temperature O C Viscosity cPs Spec grav Kg m3 pH Value Particle content Particle size mm...

Страница 43: ...WARRANTY Issue 020913 B TPUK GU31X 41 Warranty return form Sketch of installation...

Страница 44: ...ensure that all the information contained in this document is correct at the time of publication due to our policy of continuous product improvement the company reserves its right to change any inform...

Отзывы: