32
PROBLEM
No Water When Activated
Red LED stays on or fl ashes in
electronic eye (if not AC powered)
POSSIBLE CAUSE/SOLUTION
1. Replace batteries.
1. Check supply stop(s); open if closed.
2. Debris in supply hose fi lter washers in
1/2” NPSM swivel end; remove, clean
and reinstall.
3. Debris in aerator or spray head;
remove, clean, and reinstall.
1. Check surroundings for factors that
can contribute to the false triggering;
for example, bright lights, highly
refl ective surfaces, sunlight, etc.
2. Range too long; decrease sensor
range.
1. Debris in solenoid valve, won’t close
properly. Contact factory.
Very Low Flow or Slow Dribble
False Triggering
(Unit goes on by itself )
Continues to Run
(Even after power to faucet has been
reconnected)
TROUBLESHOOTING GUIDE