24
Low Battery; other power good
Transformer fail
Hydro-generator fail
Dead Battery; other power good
Transformer fail; low battery
Hydro-generator fail; low battery
Transformer fail; dead battery
Hydro-generator fail; dead battery
Dead battery; no other power
2 Second Interval
LOW BATTERY INDICATOR AND BATTERY REPLACEMENT:
POWER STATUS INDICATOR
Because the faucet can be power by a transformer, and/or a battery, and/or a hydro-
generator, the LED can display the status of power from a transformer, battery, and
hydro-generator.
LOW BATTERY INDICATOR AND BATTERY REPLACEMENT:
•
A fl ashing LED every two seconds in the sensor indicates a low battery.
•
If a transformer or hydro-generator is not connected/powered, a constant on LED
with no water fl ow indicates a dead battery.
•
If a transformer or hydro-generator is connected and powered, the LED fl ashing on
for one second then off for one second indicates a dead battery.
POWER INDICATOR
•
Two fl ashes every two seconds indicates a transformer or AC power failure
•
Three fl ashes every two seconds indicates a hydro-generator failure
When both a transformer or hydro-generator and a battery are used together,
combinations of conditions are indicated with the LED. For example, 2 fl ashes, then 1
fl ash indicate both a transformer fail and a low battery condition. See the table below:
To replace the battery:
1. Shut-off the water supply at the supply stops.
2. Using the L-Key provided, remove the lever and body screws. If the pre-set
temperature plug is installed it does not need to be removed.
3. Remove the Temperature lever from the faucet body.
4. Remove the faucet body from the base by pulling the body straight up.
5. Remove and replace the battery.
6. Carefully reinstall the body straight down onto the base.
7. Reinstall the lever, if used, and body screw.
8. Open the supply stops.