MENU ADDRESS
SETTINGS DESCRIPTION
INFORMATION
PRODUCT
Control Panel >
Network >
NETWORK PROFILES
NETWORK
When using the Network Profiles 5, 6 and 7 you can make a Network selection for the profile.
AUTO:
When set to Auto the system will parse (analyze) the number to dial and decide what network to use
based on this
H.320:
Select H.320 for an ISDN network
H.323:
Select H.323 for an IP network
SIP:
Select SIP for a SIP network
Some systems do not have ISDN (H.320). This applies to the
1700 MXP and NET versions of 3000/990/880 MXP.
All MXP
systems
Control Panel >
Network >
DATA PORT
BAUD RATE, PARITY, DATA BITS, STOP BITS
The system provides 1 - 2 standard RS232 serial ports to allow a computer to be connected for data transfer
and control purposes.
Note! When connecting to a PC, the connecting cable must be a straight through RS232 cable.
Configure the settings as required for your application:
Baud Rate (bps): 1200 - 115200
Parity: None, Odd, Even
Databits: 7, 8
Stopbits: 1, 2
A successfully connection of a PC to Data Port 1 requires that
the PC and the system are identically configured.
The control interface provided by the Data Port supports a
subset of the Hayes command set, as well as a comprehensive
set of system specific commands.
It maintains communication with the Data Port’s command
interpreter at all times. All features available from the hand-held
remote control can be accessed through the Data Port.
8000
6000
Maestro
3000
Tactical
1700
990/880/
770
550
95/85/75
Control Panel >
Network >
DATA PORT
DATA PORT MODE
CONTROL:
Gives command access, with the same interface as telnet or ssh. This is the default mode.
TRANSPARENT:
Line based text interface to far end in point to point call. The far end must also have
transparent mode enabled.
DIRECT:
Raw data interface to far end in point to point call. The far end must also have direct mode enabled.
Any data received on the local serial port is transmitted without change to the far end serial port.
OFF:
Turns the data port Off.
Control Panel >
Network >
DATA PORT 2
DATA PORT 2 SETTINGS AND MODE
Data port 2 is dedicated to the main camera and will not be available in standard configuration.
The system will automatically detect Precision HD Camera and WAVE camera. At least one of the
cameras must be connected to the data port 2. All communications settings, except the Mode setting, are
automatically configured. Exception: If Mode is Auto and no camera is connected to the Data port 2, the
Baud rate, Parity, Data bits and Stop bits settings will be enabled.
VISCA:
Select VISCA mode if the camera support the VISCA protocol.
AUTO:
Select Auto and the system will automatically detect the Precision HD Camera or WAVE cameras.
VISCA™ is a trademark of Sony Corporation
8000
6000
Maestro
D14033.06—AUGUST 2010
223
MXP
Administrator Guide
Contents
Introduction
Getting started
The menu structure
The settings library
Using the system
Physical interfaces
Peripheral equipment
Contact us
Appendices
The settings library