Symptom
Problem
Solution
selected cartridge does not contain
important data.
If this condition persists with a known-good
cartridge, contact Tandberg Technical
Support.
Fault LED: Fast blink
Servo or mechanical
error.
Power cycle or reset the drive. Try the
operation again with a known-good
cartridge. If condition persists, contact
Tandberg Technical Support.
Fault LED: Illuminated
Internal firmware error.
Power cycle or reset the drive. Try the
operation again with a known-good
cartridge. If condition persists, contact
Tandberg Technical Support.
Other LED Indications
Unspecified.
If you encounter any LED indications that
are not covered in this manual, contact
Tandberg Technical Support.
Table 5: Troubleshooting Errors Indicated by Front Panel LEDs
Table 6 helps you troubleshoot other drive and connectivity
problems.
Symptom
Problem
Solution
The drive’s SCSI ID
might not be unique.
Regardless of the number of SCSI devices
attached to the server or workstation that is
to be the host for your DLT VS160 Drive,
each must have a unique SCSI ID. Check
the SCSI IDs on all other SCSI devices on
the selected server, including the SCSI host
adapter, and select an unused SCSI ID for
your DLT VS160 Drive.
Note:
If you attach the drive to a narrow
(50-pin) bus, you can only use SCSI IDs 0
through 7.
The SCSI host
adapter might be
incorrectly configured.
Check the SCSI host adapter configuration.
Refer to the SCSI host adapter manuals for
instructions.
The host server or
workstation does not
recognize your DLT
VS160 Drive.
The SCSI cable might
be loose.
Check both ends of the SCSI cable, both for
the external and internal drives.