Using Your Tandberg DLT VS160 Drive
Tandberg DLT VS160 Installation and Operations Manual
3-3
3.2.1.2
Indicator Activity During Normal Operation:
Ready LED
When your DLT VS160 Drive is in use, the Ready LED
indicates the three states detailed in Table 2. The Ready LED
operates independently of the other three LEDs.
Ready LED
Activity
Drive Status
Off
No power to the drive
On
Power is on; no cartridge loaded or a loaded cartridge is idle with no tape
motion
Blinking
The drive is loading a cartridge or a loaded cartridge has tape motion
indicating read, write, seek, rewind, calibration, or other cartridge activity
Table 2: Ready LED Activity and Drive Status
3.2.1.3
Indicator Activity During Normal Operation:
Fault/Clean/Media LEDs
The Fault, Clean, and Media LEDs indicate the status of the
drive. Note that the LEDs can indicate more than one of the
indicated operating conditions simultaneously. For example:
•
If cleaning is required while a DLT1 format cartridge is
loaded, both the Clean and Media LEDs are on.
•
If an internal write/read diagnostic fails as a result of a
permanent write error, both the Fault and Clean LEDs
blink slowly.