53
-
The following screen can be used for notifying the
DREAM 2
system about
RTU
s which are temporarily disabled. Such RTUs will not be checked for
having communication problems, will not be send commands for execution
and will not be considered when reading inputs.
The following screen deals with changing the memory allocations made by default for
various uses. The last column shows the upper limit of each item.
◇
39
◇
40
◇
41
◇
42
◇
43
◇
39
Num. of Sequences
– defines the number of sequences that can be defined
for being used in Irrigation programs.
◇
40
Num. of Groups
– defines the number of groups that can be defined, including
constant groups and temporary groups.
◇
41
Water dosage cells
– defines the total number of irrigation jobs that can be
defined in all the sequences together.
◇
42
Fert. dosage cells
– defines the total number of fertilization jobs that can be
defined in all the sequences together.
◇
43
Virtual w. meters
– defines the number of virtual water meters that can be
defined.