50
-
◇
5
Start together
– enable synchronizing the opening of various valves by the
“
+
”
sign. The valves can be of different irrigation lines. The purpose of the
synchronization is to enable central fertilization of the valves. All the valves separated
by the
“
+
”
sign, if requiring central fertilization, will share the same central
fertilization job.
◇
6
Conditions
– enable using conditions.
◇
7
Water before special
– enable definition of a special amount of water before
fertilization for the first fertilizer of each local fert. site. This special amount differs
from the water before, used by the other fertilizers.
As a special case, when there is agitation in use, the “Water before Special” defines
the time for starting the agitation after starting the irrigation program.
◇
8
Full menu
– when full menu is enabled all the subjects are accessible by the
user, otherwise some subjects of the
SETUP
menu will not be permitted.
◇
9
◇
10
◇
11
◇
12
◇
13
◇
14
◇
15
The screen above is used for defining which of the fertilizer dosage modes will be
revealed to the user and which will remain hidden. There can be a different definition
for local and for central fertilization. The column marked
“D”
defines which mode will
be the default mode.
◇
9
L/m3
– liters of fertilizer per each cubic meter of water
◇
10
sec/ min
– seconds of injection per each minute of irrigation
◇
11
m:s/m3
– minutes and seconds of injection per each cubic meter of
water
◇
12
L/min
– liters of fertilizer per each minute of irrigation
◇
13
Volumetric prop
– the specified fertilizer quantity will be injected proportionally
to the water, the proportion will be calculated by dividing the
amount of fertilizer with the amount of water.
◇
14
By time(h:m:s)
– continuous injection of the fertilizer
quantity specified
by time
units
◇
15
Bulk(L)
– continuous injection of the fertilizer quantity specified in
liters.
◇
16
◇
17
◇
18
◇
19
◇
20
◇
21
◇
22
◇
23