Sensors Logger setting
The sampling rate of each sensor can be set at the following screen
When the storage allocated for the logger gets full, the new samples will replace the
oldest ones. Users who need to keep track of the Analog sensors readings for longer
periods can use the “Data Acquisition” feature of the
CONSOLE
and then the
information will be kept at the Data Base of the
SERVER
up to the period defined at
the administration software for analog sensors Data Retention.
9.8
Alarms definition
Alarm outputs
can be allocated in the target’s image in order to be activated in
various cases of alarm events. With the Alarm outputs various alarming devices can
be activated. The table below can be used for marking for each Alarm output in
which cases it should be activated and whether it will run continuously or in cycles.
9.9
Radiation sets definition
When using the option of triggering irrigation cycles by accumulated light, users are
required to define some parameters related with the light accumulation procedure. In
this irrigation method, instead of defining the number of cycles and the interval
between cycles, the user defines a threshold of accumulated light that whenever
reached, an irrigation cycle will take place. The needed parameters are defined
through the
Radiation sets,
including the minimal and maximal interval between
the cycles as a protection against faulty light sensor.