Takenaka System FS5100SPL Скачать руководство пользователя страница 9

N08A29;9/33 

- 9 - 

(4-5) 

Test pattern display function 

When  initially  connecting  this  camera  to  an  image  capture  board,  the 
use of the test pattern display function of the equipment makes it easier 
to  confirm  that  the  output  timing  of  the  camera  and  the  details  of  the 
signal connection match the particulars of the capture board.   
When  the  test  pattern  function  is  set  to  be  ON,  the  imaging  device 
outputs not pictures but the test pattern as shown on the right.   
As  for  this  pattern,  a  numerical  value  of  4  is  simply  added  in  an 
incremental manner for every horizontal pixel, and a saw-tooth profile is 
shown in the range from the numerical value of 0 to 1023.   
(Lower part of the right figure)   

 

(Note)  In  the  data,  a  numerical  value  of  1  is  incrementally  added  for 

every horizontal pixel in the range of 0 to 1023 for the case of 10 
bit  output,  and  in  the  range  of  0  to  255  for  the  case  of  8  bit 
output.   

(Note) The value does not start with 0 at the edge of the effective image area.   

(Note)  The  output  values  of  the  test  pattern  are  not  affected  by  the  values  of  the  gain  setting  or  offset  setting  of  the 

camera.   

 

The default setting is OFF. This setting can be changed on the configuration menu (Operation Mode Setting Group 4) or 
by way of rewriting the configuration register with serial communication commands.   
 

(4-6) Monitoring function for internal temperature of camera   

This  camera  is  equipped  with  an  internal  temperature  sensor  to monitor  the  temperature  inside  the  body.  This function 
makes it possible to use the camera in a safer way even in a harsh environment in terms of temperature, for example use 
in the open air. With the use of serial communication commands, this function also works to control the forced air-cooling 
fan of the camera and peripheral devices and others.   

 

  How to monitor internal temperature of camera   

The following two methods are available for monitoring the internal temperature of the camera:   

 

  Turn on the MENU display and confirm it by the OSD over the image. (Temperature to be displayed in Celsius) 

  Confirm  it  by  temperature  data  to  be  returned  in  response  to  the  RS-232C  command  (”RTMP”  command). 

(Numerical conversion required separately) 

 
(Note)  Carefully note that the temperature data obtained by this monitoring function is not for the ambient temperature but 

the internal temperature of the camera. As a general rule, the internal temperature of the camera is higher than the 
ambient  temperature  because  of  the  heat  generation  associated  with  the  consumed  electric  power  inside  the 
camera.   
Even when the temperature monitored by this function exceeds the value of the “Operation ambient temperature” 
shown  in  the  specifications  of  the  camera,  no  operational  trouble  will  be  caused  as  long  as  the  ambient 
temperature is equal to the one of the specifications or lower, and sufficient countermeasures against temperature 
are taken.   

 

  Detection performance for temperature data 

Temperature resolution : 

0.5° 

Update interval of data : 

0.4 sec.   

Temperature detection accuracy: 

±2°C (-40°C to +85° C), +3 to -2°C (55°C to 125°C) 

Effective data range :   

-55°C to 125°C (as long as t he operation ambient temperature of the camera is 
within the range defined by the specifications.) 

 

  Temperature data by RS-232C communication 

The temperature data to be returned in response to the “RTMP” command of RS-232C is generated in the following 
format:   

 
[Data format] 
The lower 10 bits out of the 16 bits of the returned data are valid. 
XXXXXD9D8…D0 (invalid upper 6 bits/valid lower 10 bits as the data) 
Db=B’D9D8…D0 in the binary system shows a signed integer value in two’s complement form.   
However,  the  effective  range of  the  temperature data  is  limited  to  the  following  due  to  the  operational  restriction of  the 
temperature sensor:   
Effective range of temperature data: -110 (-55°C) to  +250 (125°C) 
 
(Note) The accuracy of the values of the temperature data is not guaranteed when the operation ambient temperature is 

not within the range defined by the specifications. 

 
[Conversion method from retuned data to temperature in Celsius] 
The temperature in Celsius is computed as Tc from the following formula where Dt is the signed integer number converted 
from the above described 10 bit binary value of “Db=B’D9D8…D0”: 
 
Internal temperature of camera:    Tc=Dt×0.5°C 

Test pattern and horizontal profile 

0

1023

Содержание FS5100SPL

Страница 1: ...anage the camera properly Keep this manual at hand and reread it whenever you are uncertain about the operation Table of Contents 1 Features 3 2 Outline 3 3 Description of Each Component 4 4 How to Op...

Страница 2: ...is manual Note Particulars which require the user s attention are explained Particulars which require the user s close attention in terms of comparison with the conventional products are explained Ter...

Страница 3: ...tion of smear The ID information set by the user for each camera can be saved and read out whenever necessary via serial communication link 2 Outline Imaging device Progressive scanning interline OB O...

Страница 4: ...ns are shown in the following table Pin arrangement of Camera Link connector MDR 26 Connector Pin No Signal name Twin ax cable assignment Pin No Signal name Twin ax cable assignment 1 Insulated wire P...

Страница 5: ...DO6 O PORTA7 PORTC7 DO7 O PORTB0 PORTB4 DO8 O PORTB1 PORTB5 DO9 O Uppermost data PORTB2 3 6 7 O Fixed to L level CC1 Vinit2 I Asynchronous shutter trigger CC2 reserved I Reserved for future products C...

Страница 6: ...Procedure for switching to test pattern output 1 Set the mode switch on the rear of the camera to the position 1 2 Apply an upward stroke to the UP DOWN switch lever three times to display the menu o...

Страница 7: ...ters of PWC and others See 6 3 How to set operation mode Recommended timing of asynchronous shutter trigger signal Vinit signal for preset shutter pulse width control For the case of preset shutter mo...

Страница 8: ...continuous lighting mode the lighting in any time other than this exposure time period would be wasted Since this equipment is capable of outputting strobe signal STRB even in the continuous shutter m...

Страница 9: ...emperature data to be returned in response to the RS 232C command RTMP command Numerical conversion required separately Note Carefully note that the temperature data obtained by this monitoring functi...

Страница 10: ...s because the MSB is 1 in accordance with 1 The absolute value is 6 because of invert B 11111010 1 B 00000101 1 5 1 6 in accordance with 2 Therefore this value Dt is expressed as 6 in the ordinary sig...

Страница 11: ...ng Partial scan The read out for each frame is conducted by the partial readout scanning The vertical width of the longitudinal picture area corresponds to 790 lines at the central portion of the imag...

Страница 12: ...tch and mode setting switch it does not require the setting manipulation for the current shutter speed unlike the FC20 series products 5 3 Level setting The level setting is mostly divided into the fo...

Страница 13: ...ately saturated into a white level for the output Note The above described unnatural image represents the following states Black and white look inverted at the saturating area The outline of the satur...

Страница 14: ...1 As for this camera it must be set to be Pulse width control PWC ENABLED for implementing Pulse width control asynchronous shutter operation When it is set to be Pulse width control PWC DISABLED def...

Страница 15: ...orrection 4 Enabled disabled for pulse width control PWC ENABLED DISABLED A to F Program pages from A to F Save Load When the setting of Enabled disabled for pulse width control is not set to be ENABL...

Страница 16: ...nal value Offset Saved as the internal value Current settings Save Load Effective even after power off Lost at power off Fig 6 2 Conceptual diagram of saving and loading operations Explanation Correla...

Страница 17: ...nchronous shutter mode the repetitive trigger cyclic trigger that is generated inside the camera is automatically input Make sure to set the menu display OFF when the camera is used in the normal stat...

Страница 18: ...is to switch between 8 bits and 10 bits for the bit of the image output FORM SINGLE 1ch output is displayed as the CCD output system VSUB The setting value of Vsub voltage substrate voltage of CCD ele...

Страница 19: ...ected in CR STRB C Reflected in CR PATTERN Reflected in CR VSUB Saved as numerical value Items requiring manual save into program pages after changed on menu GAIN Saved as numerical value OFFSET Saved...

Страница 20: ...ition H 0 to H 9 or H F Where ESPE 1 externally designated number from 0 to 9 designated position is reflected In case of H F external shutter speed in H unit is selected 9 ESP 1 10 ESP 2 11 ESP 3 12...

Страница 21: ...r signal Vinit from a user device the operation mode should be set to be Asynchronous Shutter from the beginning before setting the gain and others Note When the pulse width control mode is set for th...

Страница 22: ...saved in the program pages from A to F Carefully note that the earlier setting data that were saved by the user are all overwritten and lost Fig 6 4 Setting contents immediately after reading out fac...

Страница 23: ...eturning to power on state is received even during the periods when the camera is in the operation modes of Group 2 to D Description of commands 1 Command e Function Initialization of page memory Tran...

Страница 24: ...n Command for setting shutter mode and shutter exposure time Transmission from host STX S A or M H or L N or P exposure time ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX tran...

Страница 25: ...page A to H ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The factory default is stored in the Page H which will be used when resetting to the default se...

Страница 26: ...erating the asynchronous trigger signal The internally generated trigger signal is of negative logic at 100ms 5 The minimum repetition pitch is approx 300ms Only when the trigger signal is input by th...

Страница 27: ...15 characters of the ID code character string is read out When an ID code is not set the number of the characters to be returned is 0 20 Command WVSUB Function Command for writing Vsub value CCD subst...

Страница 28: ...nd for reading preset Read PRESET Transmission from host STX RPS ETX Return by camera STX ACK RPS PRESET No ETX When gain set value coincides with gain preset value four levels of preset value corresp...

Страница 29: ...justed at the capture timing of a capture board the equal definition file to that of the conventional parallel output type can be used for capturing 8 or 10 bit x 2 tap output with 30MHz clock is empl...

Страница 30: ...ise specified the time unit of the numbers in the horizontal timing chart is H 3192CLK 3192 x 1 60 00MHz 53 2 S Vertical timing High speed preset shutter asynchronous shutter normal scan Vinit 1 11 3...

Страница 31: ...use the impact of 1H difference in exposure time over the signal level is relatively small 2 Synchronize the external trigger signal with the use of the LDV signal of the camera to keep the Vinit phas...

Страница 32: ...ower from the equipment and remove the power cable and external connection cables When an abnormal or failure condition is detected immediately stop using this equipment cut off the power supply remov...

Страница 33: ...ternal Dimensions External dimensions 21 42 46 9 2 60 26 30 7 4 31 M3 Depth Depth Depth 34 40 13 5 11 11 26 Depth Right and left sides MO DE EXP U D Camera Link I O Same as top side Depth Fig 11 1 FS5...

Отзывы: