N08A29;32/33
- 32 -
9. Notes
●
FS5100SPL is a High-resolution progressive scan color camera featuring 5 mega pixels / 9 fps, adopting single port CCD.
●
More stable image (suitable for highly accurate measurement) can be obtained by leaving the equipment for 20 or 30 minutes
after the power is turned on.
●
A longer exposure time in the pulse width control mode is accompanied by the degradation of S/N ratio due to a decrease in
the dynamic range of CCD, accumulation of thermal noise components of the CCD imaging device in proportion to the
exposure time. Therefore, it is recommended that the optimum exposure time to be employed is determined after
implementing experiments based on the conditions of the actual operation.
●
Refrain from connecting or disconnecting cables and connectors while power is being supplied, otherwise troubles may be
caused.
●
Fix a lens or implement other measures when using with a large or heavy lens, so that no extraordinarily large force is applied
to the camera.
●
This equipment is not allowed to be used for medical purposes, detection of hazardous materials or any other operations of
which performance may exert influence on human lives or safety.
●
Do not disassemble this equipment or alter the internal circuits. Accidents such as a fire may be caused by the heat
generation associated with failure in operation.
●
Connect this equipment to a high quality power source unit that does not contain noise components.
●
Take appropriate measures to control the generation of noise if a power machine or other installations in the close
neighborhood of this equipment radiates noise, which might adversely affect this equipment.
●
Do not use this equipment in an environment subject to any temperatures other than that of the specifications or
condensation, or on a place subject to considerable dust or constant vibration/impact.
●
When this equipment is not used for a long time, isolate the power from the equipment and remove the power cable and
external connection cables.
●
When an abnormal or failure condition is detected, immediately stop using this equipment, cut off the power supply, remove
the external connection cables and contact the dealer for inspection/repair.
●
The specifications and operational details described in the catalogues, manuals and others are subject to change for
performance improvement or other reasons without notice.
10. Specifications
[Specifications]
Imaging device
Progressive scanning, interline transfer CCD
2/3 inch in size
Unit cell size: 3.45
µ
m(H) × 3.45
µ
m(V): square grid pattern
Number of effective pixels 2448 (H)×2050(V)
Read out scanning
Horizontal scanning frequency: fH = 18.8KHz
Vertical scanning frequency:
fV = 9 Hz
Pixel clock frequency:
fCLK= 60.00 MHz
Standard sensitivity
500Lx at F11 *
(* Digital output with exposure time of 1/30 seconds and 512/1024 gray scale)
Minimum illuminance
10 Lx at F1.4
S/N
Approx. 46dB
Video output signal
Progressive scanning: 9Hz/frame
Output signal:
Digital output: Complied with Camera Link (Base Configuration)
8bit gray scale (30MHz × 2tap × 8 or 10bit output)
Synchronous input
Internal synchronization only
Electronic shutter
1/13000sec. to 1/ 9 sec. (no shutter) to 1/0.9 sec.
Asynchronous shutter
Preset shutter/pulse width control
Scan mode
Normal (all pixels)/partial (central area)
Lens mount
C mount (flange back fixed) * movable type: option
External control
Serial interface via Camera Link
Special functions
Function of superimposing setting information over output image
Function of monitoring internal temperature of camera
Function of storing camera ID information
Strobe output
Exposure start timing signal (+3.3V logic level)
Power supply
DC12V±10%, 360mA (max)
Operation ambient
temperature
0°C to 40°C (Shall be free from dew condensation an d frost.)
Storage temperature range -30°C to 60°C (Shall be free from dew condensation a nd frost.)
Anti-shock
70G
Anti-vibration
7G
External dimension
46(W) × 42(H) × 60(L) mm (excluding tripod attachment)
Weight
Approx. 150g