Takenaka System FS5100SPL Скачать руководство пользователя страница 3

N08A29;3/33 

- 3 - 

1. 

Features 

 

 

FS5100SPL is a full frame shutter color camera incorporated with 5 megapixel, 2/3”-size CCD image sensor. 

 

Power delivery, image data transmission and camera control are performed using single cable by adopting Power over 
Camera Link (PoCL). 

 

Single port CCD prevents the occurrence of level difference in brightness between right and left image. 

 

A  high-resolution  full  frame  shutter  color  image  can  be  obtained  when  used  in  combination  with  the  capture  board 
equipped with color conversion function (Bayer-to-RGB conversion).   

 

A full frame shutter image can be obtained at a rate of 9 frames per second.   

 

8 or 10 bit digital image signal output complying with Camera Link (Base Configuration).   

 

The internally set values of the camera can be externally controlled with serial communication via Camera Link. 

 

The character information of the current setting status of the camera can be superimposed over the captured image on 
the screen. (On Screen Display function) 

 

The monitoring function for measuring the internal temperature.   

 

The asynchronous shutter is applicable both in the preset shutter mode and the pulse width control mode. 

 

The  camera  is  designed  so  that  the  strobe  signal  can  be  output  even  in  the  continuous  shutter  mode,  and  this 
contributes to the power saving for LED lighting and others as well as the reduction of smear. 

 

The  ID  information  set  by  the  user  for  each  camera  can  be  saved  and  read  out  whenever  necessary  (via  serial 
communication link).   

 

2. Outline 

 

Imaging device 

Progressive scanning, interline 

OB

Optical Black

Effective image pickup area

2448 x 2050

SI N GL E O UT

VI DE O -L

2448

40

40

2050

4

4

4

4

 

Device size 

2/3 inch (8.45mm x 7.07mm) 

Number of pixels 

2448 (H) × 2050 (V) 

Pixel size 

3.45 

µ

m (H) × 3.45 

µ

m (V) 

Number of effective pixels 

5 megapixels 

Read 

out 

scannin

Horizontal 

18.8          KHz 

Vertical 

9                Hz 

Clock 

60.00      MHz 

Electronic shutter 

1/13000    to    1/9 second 

(

Continuous shutter and asynchronous shutter

Video output signal 

Digital 8 or 10bit (2 Tap) 

Complied with Camera Link

 (Base Configuration)

 

Scanning mode 

Normal scanning for all pixels (9 fps) 

Partial scanning for central part (18 fps) 

       
       

 

 

 

 

 

 

 

Gb 

Gb 

 

 

Gr 

Gr 

 

 

Gb 

Gb 

 

 

Gr 

Gr 

 

 

 

 

 

 

 

Color Coding 

 
The Bayer color filter array is adopted for 
a  RGB  primary  color  filter  arrangement. 
(See above chart) 
Gb  or  Gr  in  the  above  chart  represents 
Green filter on the same line as Blue filter 
or Red filter respectively. 

 

CC D

 

D

 

R

 

I

 

V

 

E

 

R

 

P

 

L

 

D

 

T

 

G

 

C

 

P

 

U

 

A/ D

 

S/H

 

V

 

i

 

n

 

i

 

t

 

R

 

X

 

D

 

T

 

X

 

D

 

V

 

i

 

i

 

n

 

t

 

2

 

V

 

i

 

n

 

i

 

t

 

1

 

S

 

T

 

R

 

B

 

M

 

O

 

D

 

E

 

S

 

W

 

P

 

L

 

D

 

Preamplifier 

 

Camera Link 

connector

 

C

h

a

n

ne

l L

in

k

 

C

am

e

ra

 L

in

k

 

B

a

se

 C

on

fig

u

ra

tio

n

 

(G A IN)

(OFF S ET )

1 0  o r 8  b it 
2  ta p  

 

CLK ,  LDV , F DV

 

U

A

R

T

 

Block chart of this equipment

 

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

R

e

l

a

t

i

v

e

s

e

n

s

i

t

i

v

i

t

y

400

Wavelength (nm)

500

600

700

450

550

650

Blue

Green

Red

( No t e ) T h e c h a r a c te r i s t i c s o f l e n s , l u m i n o u s s o u r c e e t c . a r e l e f t ou t o f c o n s i d e r a ti o n .

Typical sensitivity characteristic

 

Horizontal direction 

V

e

rt

ic

a

d

ir

e

c

ti

o

n

 

 

Содержание FS5100SPL

Страница 1: ...anage the camera properly Keep this manual at hand and reread it whenever you are uncertain about the operation Table of Contents 1 Features 3 2 Outline 3 3 Description of Each Component 4 4 How to Op...

Страница 2: ...is manual Note Particulars which require the user s attention are explained Particulars which require the user s close attention in terms of comparison with the conventional products are explained Ter...

Страница 3: ...tion of smear The ID information set by the user for each camera can be saved and read out whenever necessary via serial communication link 2 Outline Imaging device Progressive scanning interline OB O...

Страница 4: ...ns are shown in the following table Pin arrangement of Camera Link connector MDR 26 Connector Pin No Signal name Twin ax cable assignment Pin No Signal name Twin ax cable assignment 1 Insulated wire P...

Страница 5: ...DO6 O PORTA7 PORTC7 DO7 O PORTB0 PORTB4 DO8 O PORTB1 PORTB5 DO9 O Uppermost data PORTB2 3 6 7 O Fixed to L level CC1 Vinit2 I Asynchronous shutter trigger CC2 reserved I Reserved for future products C...

Страница 6: ...Procedure for switching to test pattern output 1 Set the mode switch on the rear of the camera to the position 1 2 Apply an upward stroke to the UP DOWN switch lever three times to display the menu o...

Страница 7: ...ters of PWC and others See 6 3 How to set operation mode Recommended timing of asynchronous shutter trigger signal Vinit signal for preset shutter pulse width control For the case of preset shutter mo...

Страница 8: ...continuous lighting mode the lighting in any time other than this exposure time period would be wasted Since this equipment is capable of outputting strobe signal STRB even in the continuous shutter m...

Страница 9: ...emperature data to be returned in response to the RS 232C command RTMP command Numerical conversion required separately Note Carefully note that the temperature data obtained by this monitoring functi...

Страница 10: ...s because the MSB is 1 in accordance with 1 The absolute value is 6 because of invert B 11111010 1 B 00000101 1 5 1 6 in accordance with 2 Therefore this value Dt is expressed as 6 in the ordinary sig...

Страница 11: ...ng Partial scan The read out for each frame is conducted by the partial readout scanning The vertical width of the longitudinal picture area corresponds to 790 lines at the central portion of the imag...

Страница 12: ...tch and mode setting switch it does not require the setting manipulation for the current shutter speed unlike the FC20 series products 5 3 Level setting The level setting is mostly divided into the fo...

Страница 13: ...ately saturated into a white level for the output Note The above described unnatural image represents the following states Black and white look inverted at the saturating area The outline of the satur...

Страница 14: ...1 As for this camera it must be set to be Pulse width control PWC ENABLED for implementing Pulse width control asynchronous shutter operation When it is set to be Pulse width control PWC DISABLED def...

Страница 15: ...orrection 4 Enabled disabled for pulse width control PWC ENABLED DISABLED A to F Program pages from A to F Save Load When the setting of Enabled disabled for pulse width control is not set to be ENABL...

Страница 16: ...nal value Offset Saved as the internal value Current settings Save Load Effective even after power off Lost at power off Fig 6 2 Conceptual diagram of saving and loading operations Explanation Correla...

Страница 17: ...nchronous shutter mode the repetitive trigger cyclic trigger that is generated inside the camera is automatically input Make sure to set the menu display OFF when the camera is used in the normal stat...

Страница 18: ...is to switch between 8 bits and 10 bits for the bit of the image output FORM SINGLE 1ch output is displayed as the CCD output system VSUB The setting value of Vsub voltage substrate voltage of CCD ele...

Страница 19: ...ected in CR STRB C Reflected in CR PATTERN Reflected in CR VSUB Saved as numerical value Items requiring manual save into program pages after changed on menu GAIN Saved as numerical value OFFSET Saved...

Страница 20: ...ition H 0 to H 9 or H F Where ESPE 1 externally designated number from 0 to 9 designated position is reflected In case of H F external shutter speed in H unit is selected 9 ESP 1 10 ESP 2 11 ESP 3 12...

Страница 21: ...r signal Vinit from a user device the operation mode should be set to be Asynchronous Shutter from the beginning before setting the gain and others Note When the pulse width control mode is set for th...

Страница 22: ...saved in the program pages from A to F Carefully note that the earlier setting data that were saved by the user are all overwritten and lost Fig 6 4 Setting contents immediately after reading out fac...

Страница 23: ...eturning to power on state is received even during the periods when the camera is in the operation modes of Group 2 to D Description of commands 1 Command e Function Initialization of page memory Tran...

Страница 24: ...n Command for setting shutter mode and shutter exposure time Transmission from host STX S A or M H or L N or P exposure time ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX tran...

Страница 25: ...page A to H ETX Return by camera STX ACK ETX transaction completion or STX NAK ETX transaction rejection The factory default is stored in the Page H which will be used when resetting to the default se...

Страница 26: ...erating the asynchronous trigger signal The internally generated trigger signal is of negative logic at 100ms 5 The minimum repetition pitch is approx 300ms Only when the trigger signal is input by th...

Страница 27: ...15 characters of the ID code character string is read out When an ID code is not set the number of the characters to be returned is 0 20 Command WVSUB Function Command for writing Vsub value CCD subst...

Страница 28: ...nd for reading preset Read PRESET Transmission from host STX RPS ETX Return by camera STX ACK RPS PRESET No ETX When gain set value coincides with gain preset value four levels of preset value corresp...

Страница 29: ...justed at the capture timing of a capture board the equal definition file to that of the conventional parallel output type can be used for capturing 8 or 10 bit x 2 tap output with 30MHz clock is empl...

Страница 30: ...ise specified the time unit of the numbers in the horizontal timing chart is H 3192CLK 3192 x 1 60 00MHz 53 2 S Vertical timing High speed preset shutter asynchronous shutter normal scan Vinit 1 11 3...

Страница 31: ...use the impact of 1H difference in exposure time over the signal level is relatively small 2 Synchronize the external trigger signal with the use of the LDV signal of the camera to keep the Vinit phas...

Страница 32: ...ower from the equipment and remove the power cable and external connection cables When an abnormal or failure condition is detected immediately stop using this equipment cut off the power supply remov...

Страница 33: ...ternal Dimensions External dimensions 21 42 46 9 2 60 26 30 7 4 31 M3 Depth Depth Depth 34 40 13 5 11 11 26 Depth Right and left sides MO DE EXP U D Camera Link I O Same as top side Depth Fig 11 1 FS5...