background image

Request measures to prevent water leakage under the floor and downstairs 

Use waterproof flooring materials.

If the floor has an opening, cover the opening when completing the interior finishing (waterproofing).

Install all pipe packings.

Before installation

Installation of pipes

The following are important points to adhere during the installation of pipes.

Read through the details carefully and ensure that the pipes are installed correctly.

When installing this product, ensure that installation of pipes adheres to the instructions. Installing pipes without reading 

   through the precautions will mean water may not mix properly, and a set temperature will not be achieved.

This product is designed for indoor installation. Always install this product indoors.

Precautions during installation of pipes

Water supply pipe

    ● 

The installation should be performed in conformity with the laws and regulations of the area where the product is to be installed.

Do not use pipes made of materials that may introduce rust for the water supply pipe. 

     In general, VP pipes or other materials specified by regulations in that particular region, are recommended for installation.

Ensure to install 3/8"pipes for water and hot water supply pipes and 1-1/2"pipes for drain pipes.

Always use a reamer to deburr the ends of cut pipes.

Avoid using inverted U-shaped pipes (siphon) as these can cause air to become trapped.

Always connect hot water pipes and water supply pipes after removing all contaminants such as dirt, sand and oil as these can

     cause problems.

After connecting the pipes and testing water flow, clean the filter and shower head.

The slope of the water service pipe should be determined in conformity with the laws and regulations of the area where the 

     product is to be installed.

Ensure that the drain pipe is installed at a gradient of 1/4" for a diameter of 

φ

3.0" or less, or 1/8" for a diameter of 

φ

3.0" or more.  

Do not connect the hot water pipes and water supply pipes in reverse. 

     Connecting pipes in reverse will mean the temperature of water cannot be controlled properly by the water taps, which can
     cause problems including burns.

Ensure that the hot water pipes from water boilers are only run over a short distance so as to minimize resistance. 

     Longer pipes can cause fluctuations in temperature and poor hot water delivery.

Always wrap pipes with lagging material after installation is complete.

Water boiler pipes

    ● 

In general, the same diameter and same pressure is recommended for main hot water pipes and main water supply pipes.

    ● 

Ask professional to install water boiler.

Avoid the anchor positions when installing the pipe risers.

Equipment comes with hair catchers installed.

Be sure to take the necessary precautions to prepare for and prevent possible water leaks.

2

Содержание YUME-iXi

Страница 1: ...Xi can be installed safely and to prevent any danger or risk to the person installing YUME iXi or those around them All of these precautions are important for safety Takara Belmont is not responsible...

Страница 2: ...eburr the ends of cut pipes Avoid using inverted U shaped pipes siphon as these can cause air to become trapped Always connect hot water pipes and water supply pipes after removing all contaminants su...

Страница 3: ...r softener to prevent the buildup of scale within the basin body Aeration may be minimal when using shampoo even if drinkable well water is used so a water softener should be installed Use a pressure...

Страница 4: ...crew Set for Cover Step Step low type type Maintenance Cover small Base cover Trap cover Head pillow 2 Mohair tape Maintenance Cover Installation instructions 1 Operating Manual 1 Paper template 1 YUM...

Страница 5: ...onal head bolts phillips head M8 x 50mm from the unit base four locations Detach the basin unit from the skid Carrying the Basin Unit 1 Carrying the main body Attach the carriage jig to the seat frame...

Страница 6: ...basin Do not hold the main body cover Doing so may cause damage to the main body cover Take care when handling the basin as it is heavy and fragile Do not drag the unit The foot part of the basin is...

Страница 7: ...event water leakage under the floor and downstairs Be sure to take the necessary precautions to prepare for and prevent possible water leaks Use waterproof flooring materials If the floor has an openi...

Страница 8: ...e 1 2 female screw Turn valve Not included Flexible pipe Not included Caution Before piping installation Hair trap Drain hose Turn valve and Flexible pipe is not included Prepare those parts that suit...

Страница 9: ...test the water flow to prevent accidents during use Test the water flow and inspect the following items The hot water may be slightly tainted at the start of the water flow test however this does not...

Страница 10: ...Caution Attach the two locations on the top of the step slide rail to the basin unit using truss head screws M6 x 15 2 screws Assemble while the step is retracted packing state Tighten the screws whi...

Страница 11: ...he step is installed while it is slided out this could lead to the step rattling poor sliding operation and noise Ensure the step is installed while fully retracted Fully tighten the truss head screws...

Страница 12: ...the leg rest using hexagonal head bolts M6 x 15mm 2 bolts Velcro Back support cusion Velcro Screen sheet 3 Attaching the Seat Part Attach the legrest Attach the edge of seat to the legrest by velcro...

Страница 13: ...0mm Black 6screws Remove the maintenance cover and the base cover Maintenance cover Base cover Check that pressing the reclining pedal with your foot reclines the backrest and lifting your foot off th...

Страница 14: ...s in as a fulcrum while pushing both edges inwards Position the screw sections so they pass through the trap cover attachment holes and when the screws emerge from below fix with urea cosmetic nuts Pu...

Страница 15: ...ter leaks on the floor 1 Set the neck cushion to the metal fittings in the direction as shown in the image 3 Adjust the shape of the neck cushion to suit the metal fittings and attach the basin side s...

Страница 16: ...water supply position Water supply position Drain position Wall surface or furniture Wall surface or furniture Step front back slide Figures shown above are for seating a customer about 170cm in heig...

Страница 17: ...e peeled off area The panel surface should be higher than the surrounding tile or glass surface within 1 16 or 1 8 Show the floor installation surface Caution for Anchor Bolt Installation Anchor bolts...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20 NOTE 1E043YA0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan 101 Belmont Drive Somerset NJ 08873 800 526 3847 TAKARA BELMONT CORPORATION Book Number U S A JAPAN...

Отзывы: