background image

14

6

3

2

1

1

2

3

Attaching the External Covers

Attach the trap cover to the basin unit.

The trap cover is fitted into the screw section at the bottom 
of the cover bracket under the basin, and can be attached 
using urea cosmetic nuts in 2 locations.

① 

Place the trap cover edge tabs on the edge of the frame 

       cover.

② 

Insert the trap cover as if rotating it into place with  

        the tabs in 

 as a fulcrum while pushing both edges 

        inwards.

③ 

Position the screw sections so they pass through the trap 

        cover attachment holes, and when the screws emerge 
        from below, fix with urea cosmetic nuts.

Push inwards

Push inwards

Trap cover

Base cover

The maintenance cover can be attached using magnets 
in 2 locations.

 Insert the tab at the bottom of the maintenance cover 

   

into the base cover.

 Attach the maintenance cover as if rotating it into place.

Maintenance cover

Attach the base cover to the base using 

truss-head screws.

(M4 x 10, black, 6screws)

Attach the maintenance cover.

Содержание YUME-iXi

Страница 1: ...Xi can be installed safely and to prevent any danger or risk to the person installing YUME iXi or those around them All of these precautions are important for safety Takara Belmont is not responsible...

Страница 2: ...eburr the ends of cut pipes Avoid using inverted U shaped pipes siphon as these can cause air to become trapped Always connect hot water pipes and water supply pipes after removing all contaminants su...

Страница 3: ...r softener to prevent the buildup of scale within the basin body Aeration may be minimal when using shampoo even if drinkable well water is used so a water softener should be installed Use a pressure...

Страница 4: ...crew Set for Cover Step Step low type type Maintenance Cover small Base cover Trap cover Head pillow 2 Mohair tape Maintenance Cover Installation instructions 1 Operating Manual 1 Paper template 1 YUM...

Страница 5: ...onal head bolts phillips head M8 x 50mm from the unit base four locations Detach the basin unit from the skid Carrying the Basin Unit 1 Carrying the main body Attach the carriage jig to the seat frame...

Страница 6: ...basin Do not hold the main body cover Doing so may cause damage to the main body cover Take care when handling the basin as it is heavy and fragile Do not drag the unit The foot part of the basin is...

Страница 7: ...event water leakage under the floor and downstairs Be sure to take the necessary precautions to prepare for and prevent possible water leaks Use waterproof flooring materials If the floor has an openi...

Страница 8: ...e 1 2 female screw Turn valve Not included Flexible pipe Not included Caution Before piping installation Hair trap Drain hose Turn valve and Flexible pipe is not included Prepare those parts that suit...

Страница 9: ...test the water flow to prevent accidents during use Test the water flow and inspect the following items The hot water may be slightly tainted at the start of the water flow test however this does not...

Страница 10: ...Caution Attach the two locations on the top of the step slide rail to the basin unit using truss head screws M6 x 15 2 screws Assemble while the step is retracted packing state Tighten the screws whi...

Страница 11: ...he step is installed while it is slided out this could lead to the step rattling poor sliding operation and noise Ensure the step is installed while fully retracted Fully tighten the truss head screws...

Страница 12: ...the leg rest using hexagonal head bolts M6 x 15mm 2 bolts Velcro Back support cusion Velcro Screen sheet 3 Attaching the Seat Part Attach the legrest Attach the edge of seat to the legrest by velcro...

Страница 13: ...0mm Black 6screws Remove the maintenance cover and the base cover Maintenance cover Base cover Check that pressing the reclining pedal with your foot reclines the backrest and lifting your foot off th...

Страница 14: ...s in as a fulcrum while pushing both edges inwards Position the screw sections so they pass through the trap cover attachment holes and when the screws emerge from below fix with urea cosmetic nuts Pu...

Страница 15: ...ter leaks on the floor 1 Set the neck cushion to the metal fittings in the direction as shown in the image 3 Adjust the shape of the neck cushion to suit the metal fittings and attach the basin side s...

Страница 16: ...water supply position Water supply position Drain position Wall surface or furniture Wall surface or furniture Step front back slide Figures shown above are for seating a customer about 170cm in heig...

Страница 17: ...e peeled off area The panel surface should be higher than the surrounding tile or glass surface within 1 16 or 1 8 Show the floor installation surface Caution for Anchor Bolt Installation Anchor bolts...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20 NOTE 1E043YA0 1 1 2 Chome Higashi shinsaibashi Chuo ku Osaka Japan 101 Belmont Drive Somerset NJ 08873 800 526 3847 TAKARA BELMONT CORPORATION Book Number U S A JAPAN...

Отзывы: