- 29 -
Temperatures available under the High Temperature Mode
The dark squares indicate the direction
the dipswitches should be set to.
In a Multi-Unit system, connect the
“
[3]
connector
”
and the
“
[4]
connector
”
with the
communication cable.
Please refer to the TM-MC01 manual for further instructions of the Multi-Unit system.
Connecting T-M32’s and the T-M1’s together in a
Multi-Unit System
When the T-M32 and T-M1 are connected
together in a multi-unit system to the TM-
MC01, change dipswitch No. 6 on the TM-
MC01 computer board to the “ON” position.
When the T-M32 is connected to the T-M1 as part of the Multi-unit system with the TM-RE10 or
the TM-RE30, you can set the temperature from 99ºF to 167ºF/182ºF as shown below.
NOTE:
*The maximum set temperature with the TM-RE10
When the red jumper on the back of the TM-RE10 is installed, the maximum set temperature is 167
°
F. If you remove
the jumper, the maximum set temperature will be 182
°
F.
When the set temperature is 182
°
F, “H” is displayed on the TM-RE10.
*Refer to p.31 about the TM-RE30.
99
100
102
104
106
108
110
111
113
115
117
122
131
140
158
167
99
100
102
104
106
108
110
111
113
122
131
140
149
158
167
182*
3 4 5 6 7
2
1
O N
8
Dip switch setting on
the TM-MC01
Temperatures available under the Default Mode
T-M32 Comunication Cables are included
with the T-M32. The Cables use 18 gage
wire and can be up to 250 ft. long.
Wire
[3]
(Male Adapter) and
[4]
(Female Adapter)
Multi-unit connectors are
on each unit’s computer
board.
7-Seg LED
Right bank of
dipswitches
Left bank of
dipswitches
Do not touch the Easy Link
connectors.