- 23 -
The dark squares indicate the direction
the dipswitches should be set to.
D) Normal Control (Default setting):
No.6 and No.7 OFF:
Feature:
This mode provides no special pump control. The pump operation can only be
turned ON and OFF by the TM-RE30.
Function:
If a pump is connected to the pump control terminal and both No.6 and No.7 are
OFF, the pump will be made to run all the time as long as there is a power supply to the T-
M32. The pump will stop when the TM-RE30 remote is turned off. Water in the loop will be
maintained at set temperature.
Dipswitch settings for the Pump control mode
A) Recirculation
Control
R
ight
ba
nk o
f di
psw
it
c
hes
B) Storage Tank
Circulation
Control
C) Energy
Conserving
Recirculation
D) Normal
Control
(Default)
1
O
N
23
45
78
6
1
O
N
23
45
78
6
1
O
N
23
45
78
6
1
O
N
23
45
78
6
Right bank of
dipswitches