TB7100 Service Manual
CODEC and Audio Fault Finding
367
© Tait Electronics Limited
October 2005
Task 16 —
Check CODEC 2
Device
If the DC offset measured in
is incorrect but there is no fault with
the auxiliary connector, check the CODEC 2 device.
1.
Remove the
CDC
TOP
can.
2.
Check the voltage at both ends of R241 (see
3.
If the voltages are correct, go to
. If they are not, go to
.
4.
Check for and repair any soldering faults around IC205, or else
replace IC205 (see
5.
Confirm the removal of the fault and go to
. If the repair failed, replace the main-board assembly and go
to
.
6.
Remove R241.
7.
Check the voltage at pin 3 of IC205 (see
8.
If the above voltage is correct, go to
. If it is not, replace the
main-board assembly and go to
9.
Check for and repair any soldering faults around R241 and IC205
(see
10.
Confirm the removal of the fault and go to
. If the repair failed, replace the main-board assembly and go
to
.
R241: 1.5V DC at both ends
pin 3 of IC205: 1.5V DC
Содержание TB7100
Страница 1: ...TB7100 base station Service Manual MBB 00005 01 Issue 1 October 2005...
Страница 18: ...18 Mechanical Design TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 38: ...38 Functional Description TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 62: ...62 Circuit Descriptions TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 124: ...126 Servicing Procedures TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 140: ...142 Interface Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 216: ...218 Receiver Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 340: ...342 Transmitter Fault Finding 50W 40W TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 366: ...368 CODEC and Audio Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...