TB7100 Service Manual
Frequency Synthesizer Fault Finding
189
© Tait Electronics Limited
October 2005
11.8
Power Supply for FCL
Fault-Diagnosis
Stages
Indications of a fault in the FCL will have been revealed by the initial checks
in
and the PLL checks in
. In the latter case a fault with the reference frequency
input from the FCL to the PLL will imply that the FCL is suspect. Fault
diagnosis of the FCL is divided into four stages:
■
check power supply
■
check VCXO and TCXO outputs
■
check signals at TP501 and TP502
■
check VCXO and CODEC circuitry
The checking of the power supply is given in this section in
below.
The remaining three stages are covered in
respectively. The test and
measurement points for diagnosing faults in the FCL are summarized in
Содержание TB7100
Страница 1: ...TB7100 base station Service Manual MBB 00005 01 Issue 1 October 2005...
Страница 18: ...18 Mechanical Design TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 38: ...38 Functional Description TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 62: ...62 Circuit Descriptions TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 124: ...126 Servicing Procedures TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 140: ...142 Interface Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 216: ...218 Receiver Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 340: ...342 Transmitter Fault Finding 50W 40W TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 366: ...368 CODEC and Audio Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...