TB7100 Service Manual
Frequency Synthesizer Fault Finding
191
© Tait Electronics Limited
October 2005
Task 34 —
Power Supply
If the FCL is suspect, first check that the 3 V power supply is not the cause
of the fault.
1.
If not already done, remove the main-board assembly from the chassis
and place the radio in CCTM.
2.
Measure the supply
+3
V
0
AN
at the via shown in
.
The via is adjacent to the
CDC
TOP
can.
3.
If the voltage is correct, go to
. If it is not, the 3 V regulator IC603 is suspect; go to
“Power Supply Fault Finding” on page 132
.
via adjacent to CDC TOP can: 3.0
±
0.3 V DC
Figure 11.15 TCXO circuitry under the
CDC
TOP
can
IF TOP CAN
VIA FOR MEASURING 3 V DC SUPPLY
Содержание TB7100
Страница 1: ...TB7100 base station Service Manual MBB 00005 01 Issue 1 October 2005...
Страница 18: ...18 Mechanical Design TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 38: ...38 Functional Description TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 62: ...62 Circuit Descriptions TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 124: ...126 Servicing Procedures TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 140: ...142 Interface Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 216: ...218 Receiver Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 340: ...342 Transmitter Fault Finding 50W 40W TB7100 Service Manual Tait Electronics Limited October 2005...
Страница 366: ...368 CODEC and Audio Fault Finding TB7100 Service Manual Tait Electronics Limited October 2005...