Startup and
Shutdown Limits
The user-programmable startup and shutdown limits allow for adjustable
startup and shutdown voltages. These limits can be adjusted for different
numbers of battery cells, or for the particular requirements of the base
station operation. Once the limits are reached, the PMU will shut down.
Battery Protection
Limits
The battery protection limits are set in hardware at the factory, and cannot
be adjusted by the user. These limits will not be reached under normal
operation conditions, but are provided as “fail-safe” measures to protect the
battery from deep discharge. They also remove the need for low-voltage
disconnect modules.
a. The information in this table is extracted from the TB9100
Specifications Manual.
Refer to the latest issue of this manual (MBA-00014-xx) for the most up-to-date and
complete PMU specifications.
b. Using the CSS
c. Only available if the standby power supply card is fitted.
Table 8.2
PMU DC voltage limits
a
Parameter
Voltage Range
12V PMU
24V PMU
48V PMU
User-programmable Alarms
b
Low Battery Voltage
High Battery Voltage
10V to 14V
14V to 17.5V
20V to 28V
28V to 35V
40V to 56V
56V to 70V
User-programmable Limits
bc
Startup Voltage (after shutdown)
Shutdown Voltage
12V to 15V
10V to 13.5V
23.9V to 30V
20V to 27V
47.8V to 60V
40V to 54V
Battery Protection (Fail-safe) Limits
Startup Voltage
Undervoltage Shutdown
Overvoltage Shutdown
Overvoltage Shutdown Reset
12.0V +0.3V
9.5V +0.3V
18.1V +0.3V
17.1V +0.3V
24.0V +0.5V
19V +0.5V
36.2V +0.5V
34.2V +0.5V
48V +1V
38V +1V
72.4V +1V
68.4V +1V
Содержание P25 CG
Страница 60: ...60 Installation TB9100 P25 CG Installation and Operation Manual Tait Electronics Limited January 2007 ...
Страница 72: ...72 Maintenance TB9100 P25 CG Installation and Operation Manual Tait Electronics Limited January 2007 ...
Страница 76: ...76 Troubleshooting TB9100 P25 CG Installation and Operation Manual Tait Electronics Limited January 2007 ...
Страница 120: ...120 Technical Description TB9100 P25 CG Installation and Operation Manual Tait Electronics Limited January 2007 ...
Страница 146: ...146 TaitNet P25 Glossary TB9100 P25 CG Installation and Operation Manual Tait Electronics Limited January 2007 ...