7.11. Reset all configuration data
In READY mode press
keys, it will reset all the configuration data and replace by
initial data. Be cautious in use this function.
7.12. Data transmit
The CNC-210AS has a RS-485 serial communication interface, can be used to send the winding
data to the others station. Up to 32 stations can be operated on the same network.
In this function, set station numbers to the controllers to recognize the controller to which the
current data is being send. (Refer to the section 7.2. station numbers.)
The communication bus wiring diagram as below
:
CNC-210AS
CNC-210AS
CNC-210AS
RS-485
CONNECTION BOX
COOMUNICATION CABLE(6P4C)
EARTH
TERMINATOR RESISTOR
47~100ohm
RS-485
RS-485
CONNECTION BOX
CONNECTION BOX
LAST STATION
COOMUNICATION CABLE(6P4C)
PREVIOUS STATION
In READY mode press following keys combination, its will sent each setting data to target station.
:
Sends configuration setting data to the specify station.
:
Sends winding parameters to the specify station.
:
Sends password to specify station.
It will sends from START STEP to END STEP, during sent the winding parameters,
Represents target station number. If the target station number specify as “00”, all the
stations on the same network will receive the data is being sent.