8-1
CHAPTER 8
Troubleshooting
8.1 The spindle overloads and the relay jumps.
8.1.1 The cause.
a. The drill bit is too big.
b. The feed rate is too fast.
c. Operation not in compliance with speedometer and the automatic feed rate table.
d. The fuse burned out.
e. The voltage is too low.
8.1.2The solution
a. Power
off.
b.
Open the control box.
c.
Press the relay switch to open, as shown in the
right picture, three minutes after the spindle
stops. (blue Button)
d.
Close the control box.
e. Power
on.
8.2 The spindle overloads and the fuse burns out.
8.2.1 The cause
a. The drill bit is too big.
b. The feed rate is too fast.
c. Operation not in compliance with speedometer and the automatic feed rate table.
8.2.2 The solution.
a Power
on.
b Open the control box.
c Replace the fuse as shown in the picture A.
d Close the control box.
e Power
on.
Содержание TPR1230
Страница 1: ...D E C 0 0 5 0 4 TAILIFT LTD 2006 RADIAL DRILLS TPR1230 TPR1230H TPR1600H TPR2000H Operation Manual...
Страница 11: ...1 6 z Gearbox For TPR 1230 TPR 1230H For TPR 1600H TPR 2000H z Hydraulic oil pump...
Страница 32: ...5 3 5 1 2 For TPR 1600H For TPR 2000H The front view of the machine The rear view of the machine...
Страница 74: ...9 4 9 4 Electrical circuit diagram For TPR 2000H CE Standard...
Страница 83: ...9 13 9 9 Electrical circuit diagram For TPR 1230 Standard...
Страница 84: ...9 14 9 10 Electrical circuit diagram For TPR 1230H Standard...
Страница 85: ...9 15 9 11 Electrical circuit diagram For TPR 1600H TPR 2000H Standard...