5
1.
Shut-off Valves
2.
Heat Pump Circulating Pump (M16)
3.
DHW Tank Circulating Pump (M18)
4.
Wiring Hub (knock-outs in rear of HydroBox)
4a. Low Voltage Connections
4b. Line Voltage Connections
5.
Expansion Tank
6.
Air Separator
7.
Pressure Relief Valve
8.
Hy-Vent
9.
Buffer Tank
10.
Drip Pan with Drain
11.
Touch Screen Display
12.
Heat Pump Manager Controller (SCU-1)
Get drawing showing the flow pattern through the piping –
Something that ric mayo did I believe.
With direction check valves indicated
2
3. Scope of Supply
3.1 Basic Heat Pump Components
3.2 Basic HydroBox Components
3.3 HydroBox
1) Evaporator (Air heat exchanger)
2) Fan (Water heat exchanger)
3) Switch box
4) Compressor
5) Liquefier (Water heat exchanger)
6) Accumulator
The HydroBox and integrated heat pump manager controller (SCU-1) must
be used to operate the air-to-water Heat Pump outdoor unit.
The heat pump manager is a convenient electronic regulation and control
device. It controls and monitors the entire heating and cooling system based
on the outdoor temperature, as well as domestic hot water preparation and
safety systems. All functions and programming can be accessed by the
touch screen user interface on the front panel of the HydroBox or carried
out using a smart device or smartphone paired with the unit.
e
d
.
x
e
l
p
m
i
d
n
e
l
g
.
w
w
w
7
0
0
0
D
F
·
4
0
.
6
6
.
9
6
1
2
5
4
4
English
Air-/Water-Chiller-Heatpump
3 Scope of supply
3.1 Basic device
1) Evaporator
2) Fan
3) Switch box
4) Compressor
5) Liquefier
3.2 Chiller-heat pump manager
The chiller-heat pump manager included in the scope of supply
must be used to operate the (reversible) air-/water-chiller-heat
pump.
The chiller-heat pump manager is a convenient electronic reg-
ulation and control device. It controls and monitors the entire
heating system based on the outdoor temperature or room
temperature, as well as domestic hot water preparation and
safety systems.
The sensor for outside temperature to be mounted on-site incl.
fixing materials is included with the chiller-heat pump and
chiller-heat pump manager unit.
The functions and usage of the chiller-heat pump manager are
described in the operating instructions supplied.
1
2
4
3
5
6
Fig. 1
Fig. 2
1.
Shut-off Valves
2.
Heat Pump Circulating Pump (M16)
3.
DHW Tank Circulating Pump (M18)
4.
Wiring Hub (knock-outs in rear of HydroBox)
4a. Low Voltage Connections
4b. Line Voltage Connections
5.
Expansion Tank
6.
Air Separator
7.
Pressure Relief Valve
8.
Hy-Vent
9.
Buffer Tank
10.
Drip Pan with Drain
11.
Touch Screen Display
12.
Heat Pump Manager Controller (SCU-1)
Get drawing showing the flow pattern through the piping –
Something that ric mayo did I believe.
With direction check valves indicated
2
1) Shut-off Valves
2) Heat Pump Circulating Pump (M16)
3) DHW Tank Circulating Pump (M18)
4) Wiring Hub (knock-outs in rear of HydroBox)
4a) Line Voltage Connections
4b) Low Voltage Connections
5) Expansion Tank
6) Air Separator
7) Pressure Relief Valve
8) Hy-Vent
9) Buffer Tank
10) Drip Pan with Drain
11) Touch Screen Display
12) Heat Pump Manager Controller (SCU-1)
1
2
3
4
10
5
11
12
6
7
8
9
4a
4b