37
Operation
Small type w/ automatic air-release function
ARPZD-31/61/12
40
6TCT type
PZD-30/60/100
40
Type
Page
Small type w/ relief-valve function
PZD-30R/60R/100R
CLPZD-30R/60R/100R
38
PZD-30/60/100
CLPZD-30/60/100
39
Large type
PZD-300/500
40
Small type w/o relief-valve function
✽
excluding 6TCT type
Air releasing
!
WARNING
• During the air releasing, chemical may suddenly gush out from the pipes and other parts. Lead the end
of the relief/air-release hose bank to the tank or other container, and secure it so that it will not become
disconnected.
IMPORTANT
• When using the pump for the first time or when the chemical container has been replaced, proceed with
the task of air releasing prior to operating the pump.
The air-releasing procedure will be described by pump type.
33-47̲PZD総合取説̲E.indd 37
33-47̲PZD総合取説̲E.indd 37
2010/07/20 14:24:05