COLLARING MACHINE
27
T-65CU
8. TROUBLE-SHOOTING
Problem
Cause
Remedy
The feed does not
engage.
The threading of the screw
and the nut are in the wrong
position to match each other.
Start the motor by pulling the
trigger a couple of times with
pumping movements, at the same
time turning the gear lever.
The power unit
doesn’t run.
The connection cord loose, or
the plugs do not make contact
with the wires inside the cord.
Insert the cord into the bracket,
or substitute the cord with a new
one.
Trigger not fully pressed.
Press the trigger fully.
Burrs in the tee that
has been formed
Burrs in the pilot hole:
•
The drill bit is dull
•
Lubricant insufficient
•
Lubricant of bad quality
•
Anneal Area to be drilled
•
Change drill bit
•
Use more lubricant
•
Only lubricant recommended
by T-DRILL is to be used
The forming pins are worn or
dirt stuck on their surface.
Clean or change the forming pins.
Insufficient lubricant during
forming of the outlet.
Always lubricate the T-Drill head
carefully before every outlet
forming operation.
Lubricant not suitable to the
material
Consult your local T-DRILL
representative
The wall thickness of the tube
exceeds the maximum allowable
thickness.
Consult the capacity charts
The size of the tee
varies.
Dirt stuck to the surface or the
holes of the forming pins.
Clean the forming pins.
Adjusting screws of the head are
too loose.
Tighten the screws.