PORTABLE
COLLARING SYSTEM
29
PLUS 115
10. STALLING
If the PLUS 115 is overloaded, the adapter will break and the collaring head will stall. If
this occurs, do the following:
1. Detach the power cord from the T-65 machine and remove the T-65 from the PLUS 115
unit.
2. Loosen the 4 screws of the knurled handle of the lead screw with 4 mm hex wrench
and remove the handle.
3. Remove the plug from the end of the lead screw and put the 14 mm hex wrench
through the hole of the lead screw and into the screw at the end of the collaring head.
4. Turn the hex wrench counter-clockwise four rounds and then tap the wrench with a
hammer in order to release the collaring head.
5. To remove the collaring head, tum the adapter by hand counterclockwise several
rounds and lift the lead screw and then remove the collaring head from the PLUS 115
unit.
NOTE!
¨
Before the next collar, lock the drive pin with the releasing screw and
replace the broken adapter.