OPERATION
Copyright 1995, S
YS
I
RAN
Corp.
4-10
VME3U H/W REFERENCE
SEND/RECEIVE WITH INTERRUPTS
•
Set CSR0 to ‘0010’
hex
to enable the Auxiliary Control RAM (ACR).
•
Clear the SCRAMNet
+
ACR by writing zeros to the entire address range.
•
Set the SCRAMNet
+
ACR locations that you wish to receive and/or transmit
interrupts.
•
Reset CSR0 to disable the ACR.
•
Set CSR0 to ‘F000’
hex
to insert the node and initiate the reset of the FIFOs.
•
Set CSR0 to ‘8003’
hex
to insert the node, toggle the reset of the FIFOs and
enable network activity.
•
Set CSR2 to ‘8040’
hex
to disable the fiber optic loopback mode.
•
READ CSR1 to read-out any latched error conditions.
•
READ CSR1 again to check for any existing error conditions.
•
Check for carrier detect fail (this means there are fiber optic cabling problems
from the transmitter of the node downstream).
•
WRITE a non-interrupt value to memory from at least one node. This will enable
all powered node transmitters and check for fiber optic ring integrity.
•
READ CSR1 to check for any error conditions.
•
Set CSR6 to the proper interrupt vector number.
•
Have the interrupt service routine in place.
•
Set CSR0 to ‘812B’
hex
to enable receive and transmit interrupts.
•
Set CSR0 to ‘81AB’
hex
if you wish to enable interrupt on errors.
SEND/RECEIVE WITHOUT INTERRUPTS
•
Set CSR0 to ‘F000’
hex
to insert the node and initiate the reset of the FIFOs.
•
Set CSR0 to ‘8003’
hex
to insert the node, toggle the reset of the FIFOs and
enable network activity.
•
Set CSR2 to ‘8040’
hex
to disable the fiber optic loopback mode.
•
READ CSR1 to read-out any latched error conditions.
•
READ CSR1 again to check for any existing error conditions.
•
Check for carrier detect fail (this means there are fiber optic cabling problems
from the transmitter of the node downstream).
•
WRITE a value to memory from at least one node. This will enable all powered
node transmitters and check for fiber optic ring integrity.
•
READ CSR1 to check for any error conditions.
4.7 Interrupt Conditions
Interrupts are generated under two different conditions:
•
A S network data WRITE to shared-memory
•
A S network error detected on the local node
4.7.1 Network Data WRITE
As indicated in Figure 4-2, the Transmit Enable (CSR0, bit 1) must be set before any
message can be sent. Only those nodes which have the Transmit Interrupt Enable (ACR,
bit 1) set for selected addresses send an interrupt bit out with the data packet on the
network. Only those nodes which have the Receive Interrupt Enable (ACR, bit 0) bit set
for that address will generate an interrupt signal to their host processor.
Содержание SCRAMNet+ VME3U
Страница 1: ...SCRAMNet Network VME3U Hardware Reference Document No D T MR VME3U A 0 A2...
Страница 2: ......
Страница 4: ......
Страница 52: ...OPERATION Copyright 1995 SYSIRAN Corp 4 26 VME3U H W REFERENCE Figure 4 10 Quad Switch...
Страница 72: ...CSR DESCRIPTIONS Copyright 1995 SYSIRAN Corp 5 18 VME3U H W REFERENCE This page intentionally left blank...
Страница 73: ...Copyright 1995 SYSIRAN Corp 6 1 VME3U H W REFERENCE 6 0 PHYSICAL FEATURES Figure 6 12 VME3U Layout...
Страница 76: ...PHYSICAL FEATURES Copyright 1995 SYSIRAN Corp 6 4 VME3U H W REFERENCE This page intentionally left blank...
Страница 78: ......
Страница 92: ......
Страница 96: ......
Страница 100: ...SPECIFICATIONS Copyright 1995 SYSIRAN Corp C 4 VME3U H W REFERENCE C 5 Fiber Optic Bypass Switch...
Страница 101: ...SPECIFICATIONS Copyright 1995 SYSIRAN Corp C 5 VME3U H W REFERENCE Figure C 2 Fiber Optic Bypass Switch...
Страница 102: ...SPECIFICATIONS Copyright 1995 SYSIRAN Corp C 6 VME3U H W REFERENCE Figure C 3 Housing Dimensions...
Страница 104: ......
Страница 115: ...E APPENDIX E CONFIGURATION AIDS TABLE OF CONTENTS...
Страница 116: ......
Страница 120: ...CONFIGURATION AID Copyright 1995 SYSIRAN Corp E 4 VME3U H W REFERENCE This page intentionally left blank...
Страница 121: ...F APPENDIX F ACRONYMS...
Страница 122: ......
Страница 124: ...ACRONYM Copyright 1995 SYSlRAN Corp F 2 VME3U H W REFERENCE This page intentionally left blank...
Страница 125: ...G APPENDIX G GLOSSARY...
Страница 126: ......
Страница 134: ...GLOSSARY Copyright 1995 SYSlRAN Corp G 8 VME3U H W REFERENCE This page intentionally left blank...