![Systimax AirSPEED AP542 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/systimax/airspeed-ap542/airspeed-ap542_user-manual_1423565037.webp)
Performing Advanced Configuration
SYSTIMAX® AirSPEED™ AP542
User Guide
37
Figure 4-6
DHCP Server IP Address Table - Add Entries
To edit or delete entries in the table, click
Edit
; the following window appears. Make your changes and click
OK
.
Figure 4-7
DHCP Server IP Address Table - Edit Entries
Link Integrity
The Link Integrity feature checks the link between the AP and the nodes on the Ethernet backbone. These nodes are
listed by IP address in the Link Integrity IP Address Table. The AP periodically pings the nodes listed within the table. If
the AP loses network connectivity (that is, the ping attempts fail), the AP disables its wireless interface(s). Note that
this feature does not affect WDS links (if WDS links are configured and enabled).
You can configure and view the following parameters within the
Link Integrity Configuration
screen:
•
Enable Link Integrity:
Place a check mark in the box provided to enable Link Integrity.
•
Poll Interval (milliseconds):
The interval between link integrity checks. Range is 500 - 15000 ms in increments of
500 ms; default is 500 ms.
•
Poll Retransmissions:
The number of times a poll should be retransmitted before the link is considered down.
Range is 0 to 255; default is 5.
•
Target IP Address Entry:
This entry specifies the IP address of a host on the network that the AP will periodically
poll to confirm connectivity. The table can hold up to five entries. By default, all five entries are set to 0.0.0.0. Click
Edit
to update one or more entries. Each entry contains the following field:
–
Target IP Address
–
Comment (optional)
–
Status:
Set this field to
Enable
to specify that the Access Point should poll this device. You can also disable
an entry by changing this field’s value to
Disable
.