35
4111-0024 — Apr. 2020
© 2020 Systems, LLC
Symptom
Possible Cause
Solution
Platform does not rise to
full height.
Low hydraulic fluid.
Add hydraulic fluid, see pages 26-27 for proper fluid
level and type.
Incorrect limit switch
adjustment.
Limit switch faulty or set incorrectly. See page 30 for
adjustment instructions.
Platform does not rise.
Float coil energized.
Remove the wire to the float coil, if leveler raises
relay may be faulty.
Faulty spool valve.
Remove and clean spool valve, or replace with new
valve.
Lip does not extend.
“Lip” coil not energized.
Check power to the solenoid coil; coil should have a
magnetic pull when energized.
Faulty spool valve.
Remove and clean spool valve, or replace with new
valve.
Lip does not lower.
“Lip” and “Lower” coils not
energized.
Check power to the solenoid coils; coil should have
a magnetic pull when energized.
Faulty spool valve.
Remove and clean spool valve, or replace with new
valve.
Platform does not lower.
Pump does not run.
Blue “Leveler Stored” light
not on.
Limit switch faulty or set incorrectly. See page 30 for
adjustment instructions.
Platform does not lower.
Pump runs.
Faulty prop kicker solenoid
and/or mercury switch.
Check field wiring to prop kicker solenoid and/or
mercury switch. If wiring is intact, replace prop kicker
solenoid and/or mercury switch.
Platform does not lower.
Pump runs and prop
kicker solenoid activates.
“Lower” coils not energized. Check power to the solenoid coil; coil should have a
magnetic pull when energized.
Faulty spool valve.
Remove and clean spool valve, or replace with new
valve.
Platform does not lower.
Pump runs and prop
kicker activates.
Incorrect storage prop
adjustment.
Adjust storage prop. See page 31 for adjustment
instructions.
Faulty or incorrectly set
bump-back timer in control
box.
Contact Systems, LLC Technical Services for
adjustment instructions.
Technical Service at 800-643-5424 or [email protected]
If additional troubleshooting assistance is required, contact Systems, LLC
Technical Services with equipment serial number or customer order number (CO#).