Section 3  

  Configuring the System

3.2  Discovering S6.2 units and changing IP address

SystemNet 13.0.0 supports S6, two port and six port Modular Advanced SystemNet Hubs as well 

as S6.2 and Ethernet six port SystemNet Hubs. S6.2 exclusively uses Ethernet to connect, no USB 
connection is possible unlike S6.

1. When using S6.2 you must check the S6.2/Ethernet Modular Six Port Hub Enable box, as shown 
below, you will then be presented with the main program starting with the Local Hub Network Tab.

2. Press the ‘Discover’ button, any S6.2 units discovered will populate by Discovered IP address in the 
Comms IP address box, as shown below. S6.2 units come with a DHCP setting for IP address so must 
be connected to a router with a DHCP server active.

3. If you have more than one unit you can highlight one and press the ‘Identify’ button, this will flash 

the RS232 and Bus Data lights on the unit. You can then name each unit as shown below. 

 

4. You can set a fixed IP address for each unit by entering the desired IP address and subnet mask in 
the set section, you then press ‘Set IP address’ to allocate this to the unit. The unit will reboot, if you 
rediscover it, the new IP address should be set. 

Содержание S6.2

Страница 1: ...S6 2 Controller S6 2 Controller Installation Guide...

Страница 2: ...iquid has been spilled or objects have fallen in to the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped WARNING Do Not Remove the cover There...

Страница 3: ...s Ltd Stortford Hall Industrial Park Dunmow Road Bishops Stortford Hertfordshire CM23 5GZ Web www systemline co uk Terminology This guide uses the following terminology to refer to the components of t...

Страница 4: ...nstallation 12 Installing the software on the host computer using the supplied CD ROM 12 3 2 Discovering S6 2 units changing IP address 13 3 3 Setting Touch Screen Keypad wireless junction box address...

Страница 5: ...ndow emmitter from the local input wall plate Touch screens can also control other RS232 devices such as lighting and heating control systems These must be a supported device the list of which appears...

Страница 6: ...for the S6 2 is updated via the Ethernet connection using a suitable Ethernet switch or router Two units can work on one system to give a sixteen zone system sharing RS232 devices but accessing 6 audi...

Страница 7: ...HDMI matrix or the Kramer VP 88ETH component matrix switch 11 Cables as required The following accessories are included with the S6 2 Controller 1 Systemline LRN7 Learning Remote Control 8 SAIC Audio...

Страница 8: ...ch setting to 120V Fit a 1 25mA fuse Obtain and fit a suitable 2 pin or 3 pin IEC mains cable power cord 2 3 Wiring Layout See Figure 2 Routing AV sources has not been shown for clarity 2 4 Installati...

Страница 9: ...g Mounted Loudspeakers LEFT RIGHT CIM PI DVD Player in Local Zone Wireless Junction Box Power Amplfier ZONE 1 Bookshelf or Floorstanding Loudspeakers Colour Touchscreen Keypad Display HDMI Receiver Sk...

Страница 10: ...tronics Technical Support 2 1 3 5 2 4 1 2 7 Front Panel Status Display 1 Zone Condition LEDs shows the current state of each zone RED Standby BLUE System Input RED Local Input 2 IR STATUS IR window em...

Страница 11: ...nected to a second S6 2 controller using a jack to phone cable Only available if using the phono audio input sockets 10 IR Output 3 5mm jacks for driving Window Emitters Signal is Global IR all zones...

Страница 12: ...llation 3 Click Next to install the SystemNet Configuration Utility into the default location otherwise click browse to choose the directory 4 Click Next to start the installation 5 Click Close when t...

Страница 13: ...rk Tab 2 Press the Discover button any S6 2 units discovered will populate by Discovered IP address in the Comms IP address box as shown below S6 2 units come with a DHCP setting for IP address so mus...

Страница 14: ...two wireless junction boxes with the same address on the same system even if they are on different S6 2 units Refer to the 16_zone_S6 2 snc file for guidance available from http www armourhe co uk dow...

Страница 15: ...have a second S6 2 in the system select this from the Hub drop down menu and continue the process of adding devices You should finish with all devices listed and configured they are shown to be conne...

Страница 16: ...box and then ticking the ones you wish to upload 2 Press Upload to load in a complete file including IR 3 Press Upload Without IR to upload a file without the qrc file 3 8 Keypad Configuration Profile...

Страница 17: ...the room and speakers e Balance You can offset the stereo signal to the left or right f Fixed Volume This will set the turn on volume to 30 and disable any volume adjustment this is used with AV rece...

Страница 18: ...commonly use a Sky Satellite receiver and Systemline Music Server but use different DVD players In this instance the template would simply consist of the saved settings for the Sky and Systemline pro...

Страница 19: ...set a different Modular address to avoid accidentally controlling one zone from another 4 Touch Screen Keypad Settings Note S6 2 is designed to work with colour Touch Screen Keypads 4 3 Touch Screen...

Страница 20: ...e the contrast can be set such that the screen is unreadable and therefore finding the controls to set it back again is difficult Likewise the Touch Screen Calibration can be set such that the buttons...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...All information is given in good faith The manufacturer accepts no responsibility for errors omissions or incorrect assumptions Armour Home Electronics 2010 ZINS407 ISS3 03 11 10 w w w s y s t e m l...

Отзывы: