Temperature Measurement
© 2022 System Q Ltd
22
The distance between the target and the device.
Pre-Alarm Threshold
When the temperature of target exceeds the pre-alarm threshold, and this status keeps
more than
Filtering Time
, it triggers pre-alarm.
Alarm Threshold
When the temperature of target exceeds the alarm threshold, and this status keeps
more than
Filtering Time
, it triggers alarm.
Pre-Alarm Output and Alarm Output
Check
Pre-Alarm Output
and
Alarm Output
to link the pre-alarm or alarm with the
connected alarm device.
5. Refer to
Set Arming Schedule
for setting scheduled time. Refer to
Linkage Method
Settings
for setting linkage method.
6. Click
Save
.
The maximum and minimum temperature will be displayed on the live view.
Note
Go to
Image
VCA Rules Display
to adjust the fonts size and the temperature colour of
normal, alarm and pre-alarm.
7.2.3 Set Expert Mode
Select the temperature measurement rules from
Point
,
Line
, or
Area
and configure
parameters, the device alarms if the alarm rules are met.
Steps
1. Go to
Configuration
Temperature Measurement
Basic Settings
, check
Enable
Temperature Measurement
.
2. Refer to
Set Thermography Parameters
to set the parameters.
3. Go to
Configuration
Temperature Measurement
Advanced Settings
, select
Expert
.
4. Select and enable the temperature measurement rules. Please refer to
Set Thermography
Rule
for setting the rule.
5. Optional: Click
Area's Temperature Comparison
to set the alarm rules and the
temperature.
6. Refer to
Set Arming Schedule
for setting scheduled time. Refer to
Linkage Method
Settings
for setting linkage method.
7. Click
Save
.
The maximum temperature and thermography rules will be displayed on the liveview.