Max. Capture Interval:
It describes the max. time occupation for one quick shot.
No Wearing Mask Linkage
: Check
Audible Warning
, the device will output
audio alarm if the target is not wearing mask.
Temperature Measurement
When you enable this function, the device measures the actual temperature of the
scene. It alarms when temperature exceeds the temperature threshold value.
7.1 Notice
This part introduces the notices of configuring temperature measurement function.
The target surface should be as vertical to the optical axis as possible. It is
recommended that the angle of oblique image plane should be less than 45°.
The target image pixels should be more than 5 × 5.
If multiple presets will be taken for temperature measurement, it is recommended to set
the patrol time above 20 s.
Please select line thermography or area thermography for a certain area temperature
measurement. The point thermography is not recommended in case of deviation
occurred during device movement to affect the accuracy of temperature
measurement.
7.2 Automatic Thermography
Configure the temperature measurement parameters and temperature measurement rules.
The device can measure the actual temperature and output alarms when temperature
exceeds the alarm threshold value.
7.2.1 Set Thermography Parameters
Configure the parameters of temperature measurement.
Before You Start
Go to
Configuration
System
Maintenance
VCA Resource Type
, select
Temperature
Measurement
.